Pd Free, Pd Detector, Pd Tester manufacturer / supplier in China, offering PD Free Detector GDJF-2008, GDYT Series Partial Discharge Test System, GDFR-C series High Voltage AC Voltage Divider and so on.

(/ )

Supplier Homepage Product AC/DC Hipot Test Set PD Free Detector GDJF-2008

PD Free Detector GDJF-2008

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Wuhan, China
Production Capacity: 600PCS/Year
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GDJF-2008
  • Structure: Combination
  • Signal: Continuous
  • Certification: ISO: 9001, SGS
  • Customized: Customized
  • Ambient Temperature: 0-40degree±2degree
  • Power Supply: 220V±10%, 50Hz
  • Capacitance Range to Be Tested: 6PF-250UF
  • Transport Package: Wooden Case
  • Origin: Wuhan, China
  • Task: Adjust
  • Mathematical Model: Non-Linear
  • Function: Measurement
  • Condition: New
  • Material: Aluminum Alloy
  • Relative Humidity: ≤80%
  • Earthing Requirements: Earthing Resistance <1ohm
  • Trademark: HVHIPOT
  • Specification: SGS, ISO
  • HS Code: 9030849000
Product Description
PD Free Detector GDJF-2008
GDJF-2008 Partial Discharge Detector is measuring partial discharge for the products  suchas transformers, mutual inductors, HV switches, zinc monoxide arresters and power cables. It also can make type tests and monitor insulation operation.
This type has the advantages of high sensitivity, wide range of capacitance, being wellequipped for input unit impedance detecting and more variants of frequency bands ( 9 in all). After proper setting, the discharge impulse amount can be read directly. The indicating and digital meters are shown simultaneously.
This detector is widely applied in power stations, manufacturers and institutions.

Use Condition
 
Ambient temperature: 0-40ºC±2ºC.
Relative humidity: ≤80%
Power supply: 220V±10%,50HZ.
No violent vibration and mechanical shock
The device should be placed in the environment with no dust and corrosive, good ventilation. It should not be interfered by strong electromagnetic
Earthing requirements: earthing resistance <1Ω

Capacitance range to be tested 6PF-250μF
 
Testing sensitivity (shown in Table.1)
 
Input unit
No.
Tuning capacitanceUnitSensitivity(pC)
(Unsymmetrical circuit)
16-25-100pF0.02
225-100-400pF0.04
3100-400-1500pF0.06
4400-1500-6000pF0.1
51500-6000-25000pF0.2
60.006-0.025-0.1mF0.3
70.025-0.1-0.4mF0.5
80.1-0.4-1.5mF1
90.4-1.5-6.0mF1.5
101.5-6.0-25mF2.5
116.0-25-60mF5
1225-60-250mF10
7RResistance 0.5
Table 1

Amplifier band
 
Low terminal: 10KHZ, 20 KHZ, 40 KHZ (optional)
High terminal: 80 KHZ, 200 KHZ, 300 KHZ (optional)
 
Amplifier gain adjustment
 
Coarse control - there are 6 gears for coarse tuning, the gain of each gear is 20±1db
Fine control ≥ 20 db
 
Time windows
 
Width of window, adjustable 15o-150o
Window position, adjustable 0o-170o
Two windows can be opened simultaneously or separately.
 
Discharge meter
 
Digital display
PD display: LED 3½ digits
0-100.0    limit of error <±3% (full scale)
 
Ellipse time base
 
Frequency: 50Hz and arbitrary frequency
Elliptic display color is yellow
Elliptic rotation: each gear is 30°, 180 ° rotation can be made.
Display: ellipse - straight line
High frequency time base  elliptical input voltage less than 220 V, intake power < 1 VA 
 
Waveform lock
 
Lock required waveform of any time to facilitate observation and analysis
 
Testing Voltage meter
 
Range: 100KV (Can be expanded)
Display 31/2 digital voltage meter
Accuracy: better than ±2% (full scale)
 
Inside, outside the zero mark function
 
Dimensions: 450×450×190 mm
 
Weight: about 16kg
 
Send your message to this supplier