GDDJ-DGA Transformer Oil Gas Chromatography On-line Monitoring System

Brand: HV Hipot
Customized: Customized
Portable: Non Portable
Gas: SO2
Type: Electrochemical Gas Analyzer
Product name: Transformer Oil Gas Chromatography
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDDJ-DGA
Application
Transformer Oil Gas
Atmospheric pressure
80kPa-110kPa
Transport Package
Standard Export Wooden Box
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
Production Capacity
5000set/Year

Product Description

GDDJ-DGA Transformer Oil Gas Chromatography On-line Monitoring System 

 

General Information

GDDJ-DGA Transformer Oil Gas Analyzer is an online monitoring device for dissolved gas in transformer oil based on gas chromatography technology. Potential fault are determined, release alert as per preset value through expert diagnosis system.

The device adopts distributed control sampling technology and has self-diagnosis and self-recovery functions. Each function module is weak coupling, function independent, adopting rack structure, easy for engineering maintenance.

 

 Specifications

Environmental temperature

-40ºC~+70ºC

Environmental humidity

Relative humidity 5-95%(no condensation)

Atmospheric Pressure

80kPa-110kPa

Power supply

AC 220V±10%, 50Hz

Monitoring components

H2, CO, CO2, CH4, C2H4, C2H2, C2H6, H2O, growth rate and concentration

Analysis and diagnostic function

Analyze and diagnose monitoring data by three-ratio method, David triangle method and cube diagram method. Original spectrogram can be supplied.

Min. Detection cycle

40-60mins, user-defined, default four times a day.

Sampling mode

Cycling sampling, to reflect real-time situation of inside gas.

Separating mode of oil and gas

Vacuum degassing mode, degassing for three times continuously.

Data storage lifespan

≥ 10 years

Carrier gas quantity

Self-made carrier gas, not interrupted all year round. No need to replace gas cylinder.

Monitoring gas

Measuring range

Min. detection

Error

H2

2- 2000 ppm

1 ppm

±10%

CO

5- 20000 ppm

5 ppm

±10%

CH4

0.2- 2000 ppm

0.2 ppm

±10%

C2H4

0.2- 2000 ppm

0.2 ppm

±10%

C2H6

0.2- 2000 ppm

0.2 ppm

±10%

C2H2

0.2- 2000 ppm

0.2 ppm

±10%

CO2

25- 20000 ppm

25 ppm

±10%

H2O

1 - 800 ppm

Oil temperature

-40ºC~200ºC

Total air quantity

0.2-15%

Total hydrocarbon

1 - 8000 ppm

Stability (measurement error)

At the same testing condition, error is no more than 10% for the same oil sample. (medium concentration)

IP class

IP66

GDDJ-DGA Transformer Oil Gas Chromatography On-line Monitoring System
GDDJ-DGA Transformer Oil Gas Chromatography On-line Monitoring System
GDDJ-DGA Transformer Oil Gas Chromatography On-line Monitoring System
GDDJ-DGA Transformer Oil Gas Chromatography On-line Monitoring System
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now