Gold Member Since 2011
Audited Supplier
HV Hipot Electric Co., Ltd.

Cable Identification, Grounding Fault Location, Cable Identifier manufacturer / supplier in China, offering GD-2134D Cable Identifier with Tracing and Depth Locating Function, GDYT-5/50 Partial Discharge Test System, GDYT-100/100 Partial Discharge Test System and so on.

(/ )

Supplier Homepage Product Cable Fault Locator GD-2134D Cable Identifier with Tracing and Depth Locating Function

GD-2134D Cable Identifier with Tracing and Depth Locating Function

FOB Price: Get Latest Price
Min. Order: 1 Set
Port: Wuhan, China
Production Capacity: 1000PCS/Year
Payment Terms: T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GD-2134D
  • Usage: Cable Test
  • Cable Type: Shielded
  • Certification: ISO
  • Color: Blue
  • Output Power: Max.10W
  • Display: 128*64 LCD Display
  • External Power Supply: Rated Voltage DC12V (Car Cigarette Lighter Output
  • Trademark: HV Hipot
  • Specification: ISO, SGS
  • HS Code: 9030332000
  • Test Mode: Various Frequency Method
  • Test Region: Forming Cable
  • Power: Electricity
  • Customized: Non-Customized
  • Output Frequency: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz
  • Output Voltage: Max.200V (AC Peak Value)
  • Built-in Lithium Battery: Nominal 14.8V, 7ah
  • Charger: AC 100-240V Input, 50/60Hz, Output DC 16.8V, 2A/3A
  • Transport Package: Wooden Case
  • Origin: China
Product Description
GD-2134D Cable Identifier with Tracing and Depth Locating Function
GD2134D Cable Identifier includes a transmitter and a receiver, it can be used to locate trace and depth of the underground cables and metallic pipes, also to identify the cable from a bunch of cables.

Features
 
Transmitter
 
Output (Three mode): Direct connection output, Clamp Coupling output, Radiation induction.
Frequency (6 for choice): 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, 93kHz, including 500Hz and 1kHz is complex frequency. It can realize the function of Correct/False indication and pipe identification with the help of Receiver.
Fault signal output to detect Pipe grounding fault.
Power output: Max. 10W, 4 steps adjustable.
Automatic impedance matching and functions of overload&short-circuit protection.
Power supply: Internal rechargeable Lithium battery. It can be recharged by charger (AC 220V) or car cigarette lighter (12V).
If low battery, the instrument will shut down automatically, to protect battery.
Robust and portable.
 
Receiver
 
Left/Right arrow indication for Cable Route Tracing. (Patent technology)
Correct/False indication (Patent technology). It will point to the forward when the detected cable is traced correctly. Otherwise, it will point to the backward and it will show "?".
Strong anti-interference.
Automatic measurement of depth and current.
Various detection mode, more accurate.
Detection frequency: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, 93kHz, suitable for different conditions.
Two passive detection frequency bands: power frequency and radio frequency (RF). No need to connect with audio frequency generator.
History curve display.
Cable identification: Clamp identification and stethoscope identification. Clamp identification can measure the current amplitude and direction of cable precisely and give accurate result. Stethoscope identification is a traditional method when it is not convenient to use Clamp identification. It is easy wiring for Stethoscope identification.
Grounding fault location.
Built-in Rechargeable lithium battery.
Automatic shut down if there is no operation in 30mins.
Robust and portable.
 
 
Specifications
 
Transmitter
 
Output frequency:
500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz. 500Hz and 1kHz are complex frequency. 8Hz is very low complex frequency. It is the frequency of fault location.
Output power: Max.10W for 500Hz, 1kHz, 8kHz, 33kHz and fault location. frequency. Four steps adjustable: 2.5W, 5W, 7.5W, 10W. 1W for 66kHz and 93kHz.
Output voltage: Max.200V (AC peak value), automatic adjustable according to the load.
128*64 LCD display.
Built-in Lithium battery: nominal 14.8V, 7Ah.
External power supply: rated voltage DC12V (car cigarette lighter output)
Charger: AC 100-240V input, 50/60Hz, output DC 16.8V,2A/3A.
Size: 275*220*100mm.
Weight: 2.4kg.
Working condition: Temperature -10--40ºC. Humidity 5-90% RH, Altitude<4500m.
 
Receiver

Input mode: Built-in receiving coil, Clamp, 1k Stethoscope, 8k Stethoscope, A type fault detection device.
Receiving frequency:
Active Detection Frequency For Pipes: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz And 93kHz.
Passive detection frequency: Power frequency and radio frequency (RF).
Clamp identification frequency: 500Hz, 1kHz complex frequency.
Clamp current measurement frequency: 500Hz, 1kHz, 8kHz.
Stethoscope identification frequency: 1kHz, 8kHz..
Grounding fault location frequency: 8Hz complex frequency.

 
 
Pipe detection mode:
 
Automatic Peak Method (Wide): It Is Suitable For Active Detection, With Left/Right Direction Indication. When The Frequency Is 500Hz And 1kHz, There Is Correct/False Indication.
Peak method: suitable for passive detection.
Narrow method
Null method

Cable identification mode:
Automatic Clamp identification
Clamp current measurement
Stethoscope identification
320*240 LCD display, shows signal amplitude, left/right direction, correct/false indication, history curve of signal strength, depth, current and result.
Built-in Lithium battery, rated 7.4V, 7Ah.
Charger: AC100-240V input, 50/60Hz, output DC 8.4V,2A/3A.
Size: 700*270*120mm
Weight: 3.5kg
Working condition: Temperature 0-40ºC, Humidity 5-90% RH, altitude<4500m.
 
Send your message to this supplier
Avatar
Miss Ruky
*From:
To: Miss Ruky
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category