RMS of Three Phase Voltage: Uab, Ubc, Uca.
Average Value of Three Phase AC Voltage: Uab, Ubc, Uca.
RMS of Three Phase Current: Ia, Ib, IC
Current Measurement Range: 0 ~ 100A, auto switching range;
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDBR-P
Current Measurement Accuracy
10~100A, ±(0.2%+3 digit)
Voltage Measurement Range
0 ~ 450V (phase voltage), 0 ~ 800V (line voltage)
Voltage Measurement Accuracy
100~450V, ±(0.2%+3 digit)
Frequency
45Hz ~ 65Hz
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030899090
Production Capacity
1000PCS/Year

Product Description

Features

1. Measure transformer No-load current, No-load loss, short circuit voltage, short circuit loss and capacity.
Three meters testing methods.
2. When making three phase transformer No-load, load test, the instrument will judge if the wiring is correct automatically, and shows three phase voltage, current vector diagram.
3. Finish load test under 1600kVA below distribution transformer full current for single machine. Finish 2500kVA below distribution transformer load test under 1/3 rated current (Under 1/3 rated current, the instrument can be converted to load loss parameters under rated current. )
4. All test results are corrected automatically. The instrument automatic correction as follows, waveform correction, temperature correction, Non rated voltage correction and non rated current correction. The test results are more accurate.
5. 320*240 high brightness LCD screen, with brightness adjustment. Touch buttons make the operation more convenient.
6. Real-time clock, recording test date automatically, suitable for storage and management of test results.
7. Built-in panel-type thermal printer, fast print test results.
8. Power down store and browse data (test object set, measurement results, test time) functions. Store up to 500groups test results, data transmission online to PC.
9. Allows extended range measurement for external voltage transformer and current transformer. Measure test object of any parameters.

Specifications

1. Test items
RMS of three phase voltage Uab, Ubc, Uca.
Average value of three phase AC voltage Uab, Ubc, Uca
RMS of three phase current Ia, Ib, Ic.
Percentage of No-load loss and No-load current Po, Io%.
Load loss, impedance voltage percentage, short circuit impedance Pt, ekt, Zt.
Load loss, impedance voltage percentage and short circuit impedance at any specified temperature.
Transformer actual capacity and judged capacity.


2. Insulation strength
The insulation resistance of the voltage and current input terminals to the enclosure  ≥100MΩ.
Leakage current <3.5mA.
The withstand voltage test between power input terminal and the enclosure  2kV(RMS) for 1 minutes.


3. Measurement range
Capacity 10kV Oil-immersed, dry type transformer: 30kVA ~ 2500kVA;
35kV Oil-immersed transformer: 50kVA ~ 31500kVA;
20kV Dry type transformer: 50kVA ~ 2500kVA;
35kV Dry type transformer: 50kVA~2000kVA;
Voltage  0 ~ 450V (phase voltage),
0 ~ 800V (line voltage), auto switching range
Current  0 ~ 100A, auto switching range
Frequency  45Hz~65Hz


4. Measurement accuracy
Voltage 20~100V, ±0.2%FS; 100~450V, ±(0.2%+3 digit);
Current 0.5~10A, ±0.2%FS; 10~100A, ±(0.2%+3 digit);
Power ±0.5% (CosΦ>0.1), ±1.0% (0.02<CosΦ<0.1);


5. Environment conditions
Temperature -5°C-40°C
Relative humidity <95% (25°C)
Altitude <2500m
External interference  No special strong vibration, no special electromagnetic field