• HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
  • HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
  • HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
  • HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
  • HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
  • HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing

HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing

Type: Universal Testing Machine
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Dynamic Load
Display: Digital
Control: Computer Control
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GD6900
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Top
Power supply
AC 220V±10%, 50/60Hz
High voltage output
AC 0.5KV~10KV (12kV optional)
Self-excitation power
AC 0V~50V/15A
Resolution
tgδ: 0.001%; Cx: 0.001PF
Transport Package
Plywood Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030849000
Production Capacity
3000PCS/Year

Product Description

GD6900 Transformer Insulation Resistance Capacitance and Dissipation Factor Tester
HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing


GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.


High voltage source is generated by internal inverter of the instrument, which is used for testing test object after transformer boost. If adding a insulation cup and temperature control device, dielectric loss of insulating oil can be tested.

Features
 
  1. Touch LCD screen display.
  2. Insulation resistance test: Built-in insulation resistance test module, can carry out  Insulation resistance (IR), absorption ratio (DAR), polarization index (PI) test
  1. Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
  2. The instrument data can be exported through U disk.
  3. Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
  4. Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
  5. The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
  6. High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
  7. LCR automatic measurement. Inductance, capacitance, resistance, angle can be measured and displayed.
  8. Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
  9. No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
  10. Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.


Specifications
 
Working condition -15ºC~40ºC RH<80%
Anti-interference principle Frequency conversion
Power supply AC 220V±10%, 50/60Hz Generator can be used.
High voltage output AC 0.5KV~10KV (12kV optional) Every 0.1kV
Accuracy 2%
Max. current     200mA
Capacity 2000VA
Self-excitation power AC 0V~50V/15A 50Hz, 60Hz single frequency
45HZ/55HZ  47.5HZ/52.5HZ
55HZ/65HZ  57.5HZ/62.5HZ
Automatic dual frequency
Resolution tgδ: 0.001% Cx: 0.001pF
Accuracy tgδ: ±(reading*1.0%+0.040%)
C x: ±(reading*1.0%+1.00PF)
Measurement range tgδ Without limit
C x 15pF < Cx < 300nF
10KV Cx < 60 nF
 5KV Cx < 150 nF
 1KV Cx < 300 nF
CVT test Cx < 300 nF
LCR measurement range L>20H(2kV) R>10KΩ(2kV)
LCR measurement accuracy 0.1% Resolution 0.01
CVT ratio range 10~10000
CVT ratio accuracy 0.1%
CVT ratio resolution 0.01
Insulation resistance DC high voltage 5~10kV Accuracy ±(2%*Reading +10V)
IR accuracy 100kΩ-1000GΩ: <5% (test voltage not less than 250V)
100GΩ-1000GΩ: 10% (test voltage not less than 10000V)
 
Dimension Main unit: 350(L)×270(W)×270(H)
Accessory box: 350(L)×270(W)×160(H)
Memory capacity 200 groups, USB flash disk storage is supported.
Weight Main unit: 22.75Kg
Accessory box: 5.25Kg

HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance TestingHVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing
HVHIPOT GD6900 Transformer Dielectric Loss Factor Tester with Insulation Resistance Testing

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now