Phase Current Output (Effective Value): 0-40A
Phase Current Max. Output Power: 420va
Maximum Parallel Current Output (Effecti: 0~120A
Model: GDJB-802
Customization:

Contact Supplier

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDJB-802
Product name
Relay Protection Tester
Original
China
delivery time
15 days
Transport Package
Carton or Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030820000
Production Capacity
2000PCS/Year

Product Description

Three Phase Relay Protection Tester Secondary Current Injection Test Set

General Information

GDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. In addition to the verification of various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronization, frequency, DC, intermediate, time, etc.) and microcomputer protection, it can also simulate single-phase to Three-phase transient, permanent, and transitional faults are tested for the entire set. It can also complete various large-scale and complex calibration tasks with a high degree of automation, can automatically test and scan various protection settings, store test data in real time, display vector diagrams, and print reports online.
It can independently complete device testing in professional fields such as microcomputer protection, relay protection, excitation, measurement, fault recording, etc. It is widely used in scientific research, production and electrical test sites in electric power, petrochemical, metallurgy, railway, aviation and other industries.






Features
 
1. Standard 4-phase voltage and 3-phase current output, which makes it easy to carry out and combine with various outputs for various types of protection tests. Each phase voltage can output 120V, single phase current max. Output 40A(10s), current three parallel can output 120A. The fourth phase voltage Ux is a multi-functional voltage term. It can be set as four kinds of 3U0 or synchronization voltage, or output at any given voltage value.
 
2. Single computer is easy to operate. Single computer is operated by a flexible and convenient revolving mouse through a large LCD screen. All of them are displayed in English. It can complete most of the test and verification work in the field. It can check all kinds of microprocessor-based protections relays and simulate all kinds of complex instantaneous, permanent and switching faults to carry out a whole set of tests. It can be used immediately after booting, and it is convenient and fast to operate.
 
3. Dual operation mode, connecting computer to run through a complete set of English operating software on Windows platform, can carry out various large-scale, complex and more automated verification work, can easily test and scan various protection settings, can store test data in real time, display vector diagram, draw fault waveforms, online printing reports and so on.
 
4. The software has powerful functions and can complete various large-scale and complex verification tasks with high automation, such as three-phase differential test, fast switching of auxiliary power supply, standby self-switching test, synchronous reclosure of line protection inspection, etc. It can easily test and scan various protection settings, perform fault playback, store test data in real time, display vector maps, and linked with computer and printing report, etc.
 
5. Switching quantity contacts enrich ,8 channels of contacts input and 2 pairs of empty contacts output. The input contacts are compatible with empty contacts and 0-250V potential contacts, which can be recognized automatically and intelligently. Input and output contacts can be extended according to user 's need.
 
6. Large screen LCD display adopts 320*240 dot matrix large screen high resolution graphical LCD display. All operation processes are set on the display screen. The operation interface and test results are displayed in English, and the display is intuitive and clear.
 
7. Self-protection , adopts a reasonably designed heat dissipation structure, and has reliable and perfect protection measures, soft start of power supply, and certain fault self-diagnosis and locking functions.
 
8. It has an independent dedicated DC power output , equipped with a single 110V and 220V dedicated adjustable DC power output.
 
9. High cost performance is a cross-professional joint design product, which synthesizes the advanced scientific and technological achievements of many professions. It has both the performance of large tester and the price of small tester, and has a high performance-price ratio.



Specifications 
 
AC current output Phase current output (effective value)  0-40A
Phase current max. output power 420VA
Maximum parallel current output (effective value)   0~120A
Maximum parallel power output  900VA
Long-term allowable working value of phase current (effective value) 10A
Allowable working time of maximum current 10s
Frequency range(fundamental wave)  20-1000Hz
Harmonic wave times 1-20 times
Accuracy 0.2%
AC voltage output Phase voltage output (effective value) 0~120V
Line voltage output (effective value)  0~240V
Phase voltage/Line voltage output power  80VA/100VA
Frequency range(fundamental wave) 20-1000Hz
Harmonic wave times  1-20 times
Accuracy 0.5%
DC voltage output Phase voltage output range 0~±160V
Line voltage output range 0~±320V
Phase voltage/Line voltage output power   70VA/140VA
Accuracy 0.2%
DC current output Output range 0-±10A /phase, 0-±30A /parallel
Maximum output load voltage 20V
Accuracy 0.2%
Binary input (7channels) Idle contact 1~20mA, 24V (DC)
Electric potential contact "0":0- +6V; 
 "1": +11 V- +250V
Binary output (2pairs) DC  220V/0.2A
AC   220V/0.5A
Time measurement Measurement range: 0.1ms-9999s    accuracy 0.1ms
Size 400×300×180mm³
Weight 22kg
Supply power AC 220V±10%,50/60Hz
Environmental temperature -10ºC ~ +50ºC

 
 



HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set

HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set
HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set
HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set HVHIPOT Three Phase Relay Protection Tester Secondary Current Injection Test Set

Send your message to this supplier

*From:
*To:
avatar Mrs. Karen Fan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now