Gold Member Since 2011
Audited Supplier
HV Hipot Electric Co., Ltd.

Underground cable fault locator, cable fault location, cable fault locating system manufacturer / supplier in China, offering Cable fault location set, Insulation Power Factor Test set, Partial discharge test system 10kVA. 150kV PD free testing transformer and so on.

(/ )

Supplier Homepage Product Cable Fault Locator Cable fault location set

Cable fault location set

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Wuhan, China
Transport Package: Export Package
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GD2136L
  • Output voltage: DC 0-16kV (adjustable)
  • Max.energy: 1024J, 8UF
  • Max.impulse current: 500mA
  • Cycle discharging time: 3-6 seconds
  • Altitude: <1000m
  • Specification: Dimension: 430*540*410mm
  • Input power supply: AC 220V,50Hz
  • Rated power: 1kVA
  • DC flashover voltage: 16kV
  • Discharging method: DC HV, one time, cycle
  • Insulation level: A
  • Trademark: HV Hipot
  • Origin: Wuhan, China
Product Description
General Information
GD2136L Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables.
The system contains below units:
1.GD-2131L Impulse Generator
2.GD-2132 Cable Fault Locator
3. GD-2133 Cable Fault Tester
4. Other accessories
GD-2131L Impulse Generator
It's used to generate HV impulse when using impulse flashover method to detect high impedance fault.

Features

Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased.
If working together with GD-2133 Cable Fault Tester, there are two locating ways:
a.Low voltage pulse: If only using GD-2133, open circuit and low impedance grounding faults of cable can be located, and the length of cable can be measured or wave speed of cable can be detected.
b. High voltage flashover: The discharging pulse voltage waveform of fault point is sampled by discharging sphere gap, which can locate fault distance.
Generate impulse of fixed frequency. If working together with GD-2132 Cable Fault Locator, there are following functions:
a. Audio frequency: locate high impedance, flashover faults.
b. To pinpoint cable's route, identify special cable.
c. To metallic breakdown(dead grounding), using magnetic-field measurement to locate accurately.
It also can be used in DC HV withstand test.

Specifications
Input power supply: AC 220V,50Hz
Output voltage: DC 0-16kV (adjustable)
Rated power: 1kVA
Max.energy: 1024J, 8uF
DC flashover voltage: 16kV
DC flashover current: 63mA
Max.impulse current: 500mA
Discharging method: DC HV, one time, cycle
Cycle discharging time: 3-6 seconds
Environmental temperature:0-40ºC
Humidity:<75% RH
Altitude:<1000m
Insulation level:A
Dimension:430*540*410mm
Weight:about 31kg.
GD-2132 Cable Fault Locator
Including transmitter, receiver, Inductive probe, potential type detection frame.It is suitable to test all kinds of power cable with metallic conductor.
Its main function is locating poor insulation point, detecting circuit and depth of power cable.

Features
High sensitivity
Low static drift
High accuracy of locating
Anti-interference
LCD screen to show signal and status
Built-in rechargeable Li-battery.
Specifications
Tracing and locating distance: local cable 3km, other cable up to 20km
Fault impedance resistance:0-5MΩ
Locating accuracy: ≤±10cm.
Detection cable depth: <3m.
GD-2133 Cable Fault Detector
It can test faults of short circuit, grounding, high impedance leakage, high impedance flashover fault and cable's poor connection, disconnection for all kinds of power cables (voltage degree 1kV-35kV) , local cable, communication cable, coaxial-cable and metal overhead line. It also can measure cable's length and propagation speed of electric wave speed on the cable.

Features
Safe, prompt and accurate testing. It uses LV impulse method and HV flashover detection,which test all kinds of cable faults.
Using high speed data sampling technology. A/D sampling speed is 100Mhz.
Wave form and data automatically display on big LCD screen.
Wave form and parameter storage function.
Function of comparing testing waveform of cable fault with normal waveform.
Wave form extending function.
Directly show fault point and testing point direct distance or relative distance.
Modify speed of propagation any time according to different testing cables.
Built-in rechargeable battery. Small size, portable to carry.
Specifications
Max.testing distance: 15km(Open wire up to 100km) according to customer's requirements.
Blind detection: 1m
Resolution: 1m
Power consumption: 5VA
Environmental temperature: 0-40ºC(limit temperature:-10ºC-50ºC)
Relative humidity: 40ºC(20~90)%RH
Atmospheric pressure: 86-106Kpa
Size: 275*220*160mm
Weight: 1.8kg
Other accessories
Other accessories include AF Stethoscope, Headphones, Grounding Pin, PD Locating Rack, RF Tracking Rod.




 
Send your message to this supplier