• HVHIPOT Non-linear Partial Discharge Test System/ 30kVA 100kV PD-free Detector (Customized)
  • HVHIPOT Non-linear Partial Discharge Test System/ 30kVA 100kV PD-free Detector (Customized)
  • HVHIPOT Non-linear Partial Discharge Test System/ 30kVA 100kV PD-free Detector (Customized)

HVHIPOT Non-linear Partial Discharge Test System/ 30kVA 100kV PD-free Detector (Customized)

Task: Adjust
Structure: Closed-Loop
Mathematical Model: Non-Linear
Signal: Continuous
Function: Automatic Control, Protection, Measurement
Certification: ISO: 9001
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDYT-30/100
Condition
New
Customized
Customized
Material
Aluminum Alloy
Input Power
AC380V±10% 50/60Hz±1
Voltage Output
100kV
Output Capacity
30kVA
Current Output
300mA
Voltage Accuracy
≤ 1.5%±1digit(F.S)
Current Accuracy
≤ 1.5%±1digit(F.S)
Insulation Gas
SF6 gas
PD Value
≤5PC
Rated Output Current of Control Unit
75A
Timing Range
0-999s
Transport Package
Wooden Case
Specification
30kVA. 100kV
Trademark
HVHIPOT
Origin
China
HS Code
9030849000
Production Capacity
600PCS/Year

Product Description

Partial Discharge Test System is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It is widely used in electrical manufacturing, power operation departments, research institutes and universities.
 

Features

1. 7inch color LCD screen, with PLC automation control.

2. HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high performance collection chip

3. Automatic mode and manual mode for option.

4. Display HV voltage, LV voltage, LV current, time and withstanding result.

5. Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set.

6. Zero-starting function. Test can be proceed after the voltage is back to zero.

7. Store up to 8000pcs data in 3 months. It has USB port to upload data to USB disk.

8. When setting voltage is arrived, it will timing automatically. After timing, voltage will be back to zero.

9. When the LV current is over setting value, the voltage will be cut off automatically and it will be back to zero. When the HV current is over setting value, the test object will be cut off and test can be proceed continuously.

10. With anti-interference ability, suitable for electromagnetic environment.

11.With wheels for both control unit and HV unit, easy to move.


Specifications

Power AC380V±10%, 60Hz
Capacity 30kVA
Output voltage AC 0-430V 
Rated output current 75A
HV voltmeter range 0-100kV 
Timing range 0-999s
Voltage and current accuracy ≤1.5%(F.S)±2digits
Environment temperature -20ºC to 50ºC


HVHIPOT Non-linear Partial Discharge Test System/ 30kVA 100kV PD-free Detector (Customized)
 