• HVHIPOT GDYB Series Three Phase Electric Energy Meter Test System
  • HVHIPOT GDYB Series Three Phase Electric Energy Meter Test System
  • HVHIPOT GDYB Series Three Phase Electric Energy Meter Test System
  • HVHIPOT GDYB Series Three Phase Electric Energy Meter Test System
  • HVHIPOT GDYB Series Three Phase Electric Energy Meter Test System
  • HVHIPOT GDYB Series Three Phase Electric Energy Meter Test System

HVHIPOT GDYB Series Three Phase Electric Energy Meter Test System

After-sales Service: Yes
Warranty: 1 year
Display: Digital
Installation: Direct Connected
Usage: Standard Electric Energy Meter
Electric Equipment: Three-phase Four-wire
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDYB Series
Theory
Machine-electric Type
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
ISO
Customized
Non-Customized
Measure Various Single/Three pH
Accuracy Level: 0.1 Class
Output Voltage
3*100V/57.7V Y 3*100V
Regulating Range
0-120%
Regulating Accuracy
Better Than 0.01%
Symmetry of Three Phase
Better Than 120+0.3
Frequency Range
45Hz-65Hz
Transport Package
Wooden or Box
Specification
ISO9001
Trademark
HV Hipot
Origin
Wuhan, China
HS Code
9031809090
Production Capacity
5000/Year

Product Description


General Information 

GDYB series Meter Test System is used to measure various kinds of single/three phase meters of 0.1% and below. It has good 
appearance, complete functions, and excellent performance.
 
Main Features&Functions

1. Compact design, the meter rack of the testing equipment and the desk frame are all made of special aluminum alloy and the desk 
faceplate is made of fireproof and heatproof fiber material.
2. Easy to use, both keyboard and PC operation are available.
3.Advanced automation. User only needs to put on meters, adjust the photoelectric sampler and set the parameters in good condition, 
then all the test items, including pre-heating, actuation and false actuation tests, standard deviation test, basic error test are all controlled by PC by one test. The procedure 
of meter calibration can be user-defined.  
4. Photoelectric sampler can realize three-dimensional adjustment. It can not only sample the turn-plate signal of the rotary meter but also receive the strobe signal of the electronic meter.
5. The error processing system can receive signal from the photoelectric sampler and output pulse of the insert type electronic meter, and high frequency pulse signal of standard meter.
6. Meters in same type(same phase line, rated voltage, calibrated current) but different constant (at most 3 kinds) can be test at same 
time.
7. Test RS485 communication function of multi-functional meter, required error and clocking error (Time signal output is necessary).
8. Locate the mark area of rotary meter automatically, which enables easier false actuation tests.
9. Superimposing 2-21 harmonics in fundamental wave of power frequency, harmonic amplitude and phase can be set according the 
requirements. Also harmonic analysis and draw waveform can be performed for output components.
10. Auto testing on every unit voltage, current, power stability and three phase total power stability. 
11. High stability and reliability, which can provide strong output power. Voltage (current) loop can take load of any type.
12. The testing equipment is provided with complete malfunction checking, locating, protecting and alarming functions to avoid damaging 
of the bench  resulted from wrong manual wiring or operating.
13. PC software developed with Delphi for Windows 95 provides fast and  effective equipment control and data checking, it also provides complete  functions, such as report printing, quantity counting and assets maintaining
 
Specification
 
Accuracy level 0.1%
Output voltage 3*100V/57.7V Y   3*100V 
3*380V/220V Y    3*380V 
Regulating range 0-120% consecutively adjustable 
(Special voltage range can be setup according to actual order.)
Regulating accuracy better than 0.01%
Current range 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, 50A, 100A
Regulating range 0-120% consecutively adjustable
Regulating accuracy better than 0.01%
Output power (voltage loop) GDYB-S18  800VA
(current loop) GDYB-S18  1500VA
Stability of output voltage, current and power ≤0.05%/120S      PF=1 (level O.1type)
Wave distortion of output voltage and current ≤0.5%
Symmetry of three phase better than 120°+0.3°
Frequency range 45Hz-65Hz 
Regulating accuracy  0.1 Hz
Phase shifting range  -180.0°~180.0°
Regulating accuracy 0.1°
Standard crystal oscillator stability  ≤10-7/s
Indicating instruments class Voltmeter and ammeter accuracy: level ±0.2%
Phase meter accuracy: ±0.5°
Frequency meter accuracy: ±0.1Hz
Maximum meters for test 18
Power supply 3*220V±10%, 50Hz
Maximum power consumption 4000VA
Working temperature 20±5ºC
Relative humidity ≤85%
Dimensions 2500mm*720 mm*1900mm
Weight 350Kg

HVHIPOT GDYB Series Three Phase Electric Energy Meter Test SystemHVHIPOT GDYB Series Three Phase Electric Energy Meter Test SystemHVHIPOT GDYB Series Three Phase Electric Energy Meter Test SystemHVHIPOT GDYB Series Three Phase Electric Energy Meter Test SystemHVHIPOT GDYB Series Three Phase Electric Energy Meter Test SystemHVHIPOT GDYB Series Three Phase Electric Energy Meter Test System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now