GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker

Product Details
Customization: Available
Input power: AC220V±10% 50Hz±1
Capacity: 200kVA
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
  • GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
  • GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
  • GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
  • GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
Find Similar Products

Basic Info.

Model NO.
GDYT-20/200
HV Voltage
200kV
LV Voltage
0.38/0.6kV
Timing range
0-999s
Environmental temperature
-20ºC--50ºC
Voltage accuracy
≤ 1.5%±1digit(F.S)
Current Accuracy
≤ 1.5%±1digit(F.S)
Delivery time
30 working days
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030899090
Production Capacity
2000PCS/Year

Product Description

GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker or Capacitance Bushing
GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker

Overview:

GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System is mainly used for power frequency withstand voltage, partial discharge and other scientific test research of transformers, power transformers, high voltage circuit breakers, coupling capacitors, capacitor bushing, switches and other test products.

 
Working condition:
 
Altitude: ≤3000m

Ambient temperature: -15 ° C to +40 ° C

Maximum daily temperature difference: ≤25ºC

Air relative humidity: ≤ 90% (20ºC)

Earthquake resistance: ≤8

The ground horizontal acceleration is 3.0m/ S2, and the ground vertical acceleration is 1.5m/ S2

The waveform of the supply voltage is the actual sine wave, and the waveform distortion rate is less than 3%

Provided with a reliable ground point, ground resistance < 0.5ω

Installation location: indoor

 

The system includes:  

1.GDYD-20kVA/200kV power frequency voltage test device          1 set

2.YDQW gas type pd free high voltage testing transformer(20kVA/200kV)    1 set

3. LBQ-200 isolation filter device 20kVA/ 0.4KV         1 set

4. T
AWF-200/1000 coupling capacitor 200kV/800PF   1 set

5. GR-5 pd free high voltage protection resistance 200kV/15 kω       1 piece

6. Partial discharge detector GDJF-2007          1 set



Specifications

Model No. GDYT-200/200
Capacity 200kVA
HV Voltage 200kV
High voltage current;
LV Voltage;
100mA
50A

For detail specifications, please contact me soon.

GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
GDYT-20/200 20kVA 200kV Partial Discharge PD Free Test System/Set for HV Circuit Breaker
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier