• HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor  Tester
  • HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor  Tester
  • HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor  Tester
  • HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor  Tester
  • HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor  Tester
  • HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor  Tester

HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor  Tester

After-sales Service: Yes
Warranty: 1 year
Type: Universal Testing Machine
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Dynamic Load
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
GD6900
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Working condition
-15ºC~40ºC;RH<80%
Power supply
AC 220V±10%, 50/60Hz.Generator can be used.
High voltage output
AC 0.5KV~10KV (12kV optional)
Transport Package
Standard Wooden Package
Specification
ISO, SGS
Trademark
HV HIPOT
Origin
Wuhan China
Production Capacity
5000PCS/Year

Product Description

GD6900 Capacitance and Dissipation Factor Tester

HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor Tester
Product Description

GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.

High voltage source is generated by internal inverter of the instrument, which is used for testing test object after transformer boost. If adding a insulation cup and temperature control device, dielectric loss of insulating oil can be tested.Features
 

  1. Touch LCD screen display.
  2. Insulation resistance test: Built-in insulation resistance test module, can carry out  Insulation resistance (IR), absorption ratio (DAR), polarization index (PI) test
  1. Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
  2. The instrument data can be exported through U disk.
  3. Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
  4. Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
  5. The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
  6. High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
  7. LCR automatic measurement. Inductance, capacitance, resistance, angle can be measured and displayed.
  8. Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
  9. No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
  10. Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
    Product Parameters

    Specifications

    Working condition -15ºC~40ºC RH<80%
    Anti-interference principle Frequency conversion
    Power supply AC 220V±10%, 50/60Hz Generator can be used.
    High voltage output AC 0.5KV~10KV (12kV optional) Every 0.1kV
    Accuracy 2%
    Max. current     200mA
    Capacity 2000VA
    Self-excitation power AC 0V~50V/15A 50Hz, 60Hz single frequency
    45HZ/55HZ  47.5HZ/52.5HZ
    55HZ/65HZ  57.5HZ/62.5HZ
    Automatic dual frequency
    Resolution tgδ: 0.001% Cx: 0.001pF
    Accuracy tgδ: ±(reading*1.0%+0.040%)
    C x: ±(reading*1.0%+1.00PF)
    Measurement range tgδ Without limit
    C x 15pF < Cx < 300nF
    10KV Cx < 60 nF
     5KV Cx < 150 nF
     1KV Cx < 300 nF
    CVT test Cx < 300 nF
    LCR measurement range L>20H(2kV) R>10KΩ(2kV)
    LCR measurement accuracy 0.1% Resolution 0.01
    CVT ratio range 10~10000
    CVT ratio accuracy 0.1%
    CVT ratio resolution 0.01
    Insulation resistance DC high voltage 5~10kV Accuracy ±(2%*Reading +10V)
    IR accuracy 100kΩ-1000GΩ: <5% (test voltage not less than 250V)
    100GΩ-1000GΩ: 10% (test voltage not less than 10000V)
     
    Dimension Main unit: 350(L)×270(W)×270(H)
    Accessory box: 350(L)×270(W)×160(H)
    Memory capacity 200 groups, USB flash disk storage is supported.
    Weight Main unit: 22.75Kg
    Accessory box: 5.25Kg
HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor TesterHV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor TesterHV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor TesterHV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor Tester
Company Profile

HV HIPOT GD6900 Transformer Insulation Resistance Capacitance and Dielectric Loss Factor Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now