HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • Automatic Calibration: Automatically calibrates SF6 density relays and pressure gauges with embedded microprocessor.
  • Portable Design: Compact, lightweight, and easy to carry for field operations.
  • High Accuracy: Class 0.25 accuracy with 0.0001Mpa pressure resolution.
  • Safety Protection: Built-in voltage protector prevents device damage from misconnection.
  • Gas Saving: Good sealing property avoids wasting SF6 gas during calibration.
  • Direct Printing: Equipped with mini-printer to directly print test results.
  • UPS Power Supply: Power supply includes UPS function for reliable field operation.

Product Images of HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)

HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A) pictures & photos
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A) pictures & photos
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A) pictures & photos
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A) pictures & photos
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
  • HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
  • HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
    HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
  • HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
    HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
  • HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
    HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
  • HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)
    HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)

Find Similar Products

Product Description

General Information

GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. It is also a portable device which can make standard conversion for SF6 gas pressure at any environmental temperature. This device is mainly used for SF6 gas products production, maintenance and monitoring in power system.


Features

1. Automatically calibrate density relay and pressure gauge.

2. Compact design, small size, and light weight, easy to carry.

3. Color LCD screen, WINDOWs menu.

4. The power supply has UPS function, suitable for field operation.

5. With mini-printer, to print test result directly.

6. Good sealing property, do not waste SF6 gas during calibration.

7. The two ends of connection pipe has fast check valve, easy operation and avoid water and air entering into the pipe. No need to dismantle most of density relay to calibrate directly.

8. There is automatic voltage protector for sampling point. If sampling point clip misconnecting with 220V voltage, it will not destroy device.


Functions


1. Automatically measure pressure when SF6 gas density relay alarm or disalarm at any environmental temperature. It also can convert it to standard pressure at 20ºC, to realize alarm performance calibration.

2. Automatically measure pressure when SF6 gas density relay interlock or relive interlock at any environmental temperature. It also can convert it to standard pressure at 20ºC, to realize interlock performance calibration.

3. If there is pressure gauge or density meter of tested SF6 gas density relay, it can calibrate the accuracy of pressure gauge or density meter.

4. Convert the SF6 gas pressure into standard pressure at 20ºC.

5. Convert the standard pressure at 20ºC into pressure at any temperature.

6. Set multiple measurement for one density relay. The measurement result is average value.



Technical Specifications
 
Power supply AC/DC use, built-in rechargeable battery, AC 220V±10%, 50Hz.
Accuracy Class 0.25
Display 3.5inch true color LCD screen.
Printer Needle type microprinter
Measurement pressure range 0-1.0Mpa
Calibration pressure range standard pressure 0-0.9Mpa at 20ºC.
Temperature range -50ºC--100ºC
Dimension 258*240*88mm
Weight about 2.5kg
Pressure resolution 0.0001Mpa
Temperature resolution 0.1ºC
Storage capacity 50-100pcs
Communication port USB2.0


Accessories
 
Tester 1 piece
Connector 1 set, total 18pcs
Gas pipe for storage gas cylinder 2pcs
Sampling lead of calibration point 2pcs
Connection pipe of relay 1 piece
Inlet pipe 1 piece
Outlet pipe 1 piece
Charger 1 piece
Small cylinder 1 piece
USB data cable 1 piece
Printer 1 roll
Spanner 1 piece
YQD-6 Nitrogen pressure reducer 1 piece
User's guide 1 copy
Test report 1 copy
HVHIPOT Automatic Calibrator of SF6 Density Relay (GDJD-3A)

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the warranty period for this device?
We provide a 1-year warranty for the HVHIPOT Automatic Calibrator.
Can this device calibrate SF6 density relays automatically?
Yes, it automatically calibrates density relays and pressure gauges using an embedded microprocessor.
What is the measurement accuracy of the calibrator?
The device has a Class 0.25 accuracy with a pressure resolution of 0.0001Mpa.
Is the device portable for field use?
Yes, it features a compact design, small size, and light weight (about 2.5kg) for easy carrying.
What is the delivery time for this product?
The standard delivery time is 20 days.
Does the device have safety protection features?
Yes, it includes an automatic voltage protector to prevent damage if the sampling point is misconnected with 220V.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now