HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • Customized Output Voltage: Output voltage ranges from 0-50kV to 0-200kV based on specific requirements.
  • Customized Output Current: Output current options range from 0-50A to 0-2000mA for flexible testing.
  • Wide Timing Range: New type time relay supports timing from 1 second up to 99 hours.
  • Digital Display Controls: Features easy-to-read digital display panel with mounted controls and indicators.
  • Comprehensive Protection: Includes over-current protection, zero-starting protection, and sound/light alarms.
  • Adjustable Trip Levels: Over-current protection trip levels are adjustable from 10% to 110%.
  • Lightweight and Portable: Designed with small size and light weight for easy movement and handling.

Product Images of HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D

HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D pictures & photos
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D pictures & photos
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D pictures & photos
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D pictures & photos
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D pictures & photos
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
  • HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
  • HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
    HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
  • HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
    HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
  • HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
    HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
  • HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
    HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
  • HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D
    HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D

Find Similar Products

Product Description

General information

AC Hipot testing is the effective and direct way to test insulation strength for electric equipments,apparatus or machines.It checks dangeous flaws which assure electric equipment continuous working.Typical applications include testing of transformers, switchgear, cables, capacitors,aerial motors platforms,hot sticks bucket bricks,vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes,gloves,hydraulics hose,instruments transformers generators.


Features

1. Digital display panel mounted controls & indicators with easy to read legend.
2. Monitoring high voltage side voltage,low voltage side current and indicator of zero, power, working start,timing.
3. Over-current protection,zero-starting protection,sound and light alarm.
4. Continuously variable output from zero to full voltage.
5. Adjustable over current protection,with trip levels variable from 10 to 110%.
6. With new type time relay,time rang is more wider (1S ~ 99H).
7. Using the latest current relay, more accurate and reliable.
8. Light weight,small size,easy to move.


Technical Specifications
 
Input voltage AC 220V or 380V
Output voltage of control unit AC 0-250V or 0-430V
Output current of control unit 0-5/10/15/50A(customized)
Output power(Capacity) 0-3/5/10/15/20kVA(customized)
Output voltage of HV unit 0-50/100/150/200kV(customized)
Output current of HV unit 0-50/100/150/200/500/1000/2000mA(customized)
Timing 0-9999s
Environmental temperature -20ºC--50ºC
Voltage accuracy ≤ 1.5%±1digit(F.S)
Current accuracy ≤ 1.5%±1digit(F.S)


Other accessories for option

1. AC/DC Digital Voltage Meter: 50,100,150,200kV
2. Sphere Gap
3. DC microammeter
4. Discharge stick
5. Water resistor
6. HV filter capacitor: 0.01μF-0.1μF, 40-300kV
7. Trolley
8. Insulating support: 50,100,200,300kV
9. Standard Oil cup: 400ml
10. HV electroscope: 10, 35kV
 
HVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-DHVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-DHVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-DHVHIPOT AC/DC Hipot Dielectric Withstand Test Set GDYD-D

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the output voltage range?
The output voltage is customizable, ranging from 0-50kV to 0-200kV.
Can the output current be customized?
Yes, the output current is customizable, with options from 0-50A to 0-2000mA.
What is the maximum timing duration?
The timing range is wide, extending from 1 second up to 99 hours.
Does the device have protection features?
Yes, it includes over-current protection, zero-starting protection, and sound/light alarms.
Is the output voltage adjustable?
Yes, the device offers continuously variable output from zero to full voltage.
What are the input voltage options?
The input voltage supports AC 220V or 380V.
Is the equipment portable?
Yes, it is designed to be lightweight and small in size for easy movement.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now