| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | 1 year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Voltage |
Guarantee error range | 25-600V | |||
| Starting measuring value | 0.5V | ||||
| Rated value | 440V | ||||
| Error accuracy | ±0.05% | ||||
Current |
Terminal | Rated Ie | 5A | ||
| Range | 0.025A-12A | ||||
| Clamp | Rated Ie | 5A, 100A, 500A,1000A (optional) | |||
| Range | 0.5%Ie-2.4Ie | ||||
| Starting current | 0.02%Ie | ||||
| Input frequency range | 45-65Hz | ||||
| Frequency measuring error | ±0.01Hz | ||||
| Phase angle measuring range | -180°- 180° | ||||
| Max. Phase angle error | ±0.1° | ||||
| Harmonic percentage, harmonic electrical parameters, and harmonic electric energy measurement times | 2-51 times | ||||
Pulse constant (Note: Ie is rated current) |
Low frequency output (3 gears) |
5A | 3600P, 36000P, 360000P/kWh(kvarh, kVAh) | ||
| others | 3600P, 36000P, 360000P *(5/Ie)P/kWh (kvarh, kVAh) |
||||
| Internal high frequency | 5A | 1.8x109 P/kWh | |||
| Other current gears | 1.8x109 *(5/Ie)P/kWh | ||||
| Maximum pulse input frequency | 50kHz | ||||
5A terminal |
Full-wave fundamental wave kWh, P, U, I | ±0.05% | |||
| Full-wave fundamental wave Kvarh, Q, VA, VAh |
±0.2% | ||||
| Harmonic wave U, I, P, Q, S | ±0.2%H (H=1+0.01k K=2-51) | ||||
5A clamp |
Full-wave fundamental wave kWh, P, U, I | ±0.2% | |||
| Full-wave fundamental wave Kvarh, Q, VA, VAh |
±0.2% | ||||
| Harmonic wave U, I, P, Q, S | ±0.5% H (H=1+0.01k K=2-51) | ||||
| Self checking current cyclic output current | 0.05A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A | ||||
| Self checking error (linear and angular difference) | ±0.1% | ||||
Big current clamp |
Full-wave fundamental wave kWh, P, U, I | ±0.5% | |||
| Full-wave fundamental wave Kvarh, Q, VA, VAh |
±0.5% | ||||
| Harmonic wave U, I, P, Q, S | ±1.0% H (H=1+0.01k K=2-51) | ||||
Others |
Ratio measurement | ±0.5% | |||
| Voltage influence | < ±0.01% | ||||
| Frequency influence | < ±0.01% | ||||
| Temperature influence | < ±0.005%/ºC | ||||
| 24hours change error | < ±0.01% | ||||
| Harmonic influence | < ±0.01% | ||||
| Rechargeable battery | 11.1V 3000mAh | ||||
| Withstand voltage (Voltage current measurement and power supply and low-voltage terminals) | 4.0 kV | ||||
| Electrical Fast Transient Burst | 4.0 kV | ||||
| Surge | 4.0kV (Common mode), 2.0kV (Differential mode) | ||||
| Standby time after start-up | <3 minute | ||||
| Ambient temperature | -25ºC-+45ºC | ||||
| Relative humidity | 40%-95% | ||||
| Working power supply | AC 55V - 600V | ||||
| Power consumption | < 9W | ||||
| Dimension | 275mm * 196mm * 78mm | ||||
| Weight | < 1.5 kg | ||||