HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
  • HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
  • HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
  • HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
  • HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
  • HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
Find Similar Products

Basic Info.

Model NO.
GDP-311IR
Type
Universal Testing Machine
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Measuring range
0 ~ 100% SF6
Response time
[90%] 60s
Resolution
0.01%
Display unit
%
Gas flow rate
400 ~ 600ml/min
Transport Package
Standard Export Wooden Box
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
HS Code
9030899090
Production Capacity
5000set/Year

Product Description

SF6 gas purity tester purity analyzer GDP-311IR

GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of SF6 gas purity analyzer.

Application

Analysis purity of SF6 gas electrical equipment for electric power
SF6 gas cylinder gas quality test
Quality test of SF6 gas for recovery and reuse
High purity gas manufacturing
Semiconductor industry dry gas supply
Research and development use
Clean room/dry house monitoring

Features
 
  1. Imported high-precision sensors with self-calibration function, ensure the stability and reliability of purity detection data throughout the year.
  2. All gas path with high polymer material design, ensures no water wall hanging phenomenon and guarantees the test speed.
  3. The oil-free stainless-steel body regulating valve is used to ensure the accuracy of the measured value.
  4. Advanced software algorithms improve the test accuracy of sensors.
  5. Combined chassis configuration solution, users can easily combine related instruments and accessories. The overall package is carried, which makes the user have a more relaxed experience.
  6. Startup test, no need to oscillate.
  7. Temperature conversion and pressure data correction.
  8. Fuzzy computing technology.
  9. High-power lithium battery power, realize AC and DC dual power supply. No on-site AC power is required. Lithium battery power supply continues to work for more than 8 hours without the need of an external power supply.
  10. Anti-electromagnetic interference circuit design to ensure product reliability.
  11. Large-capacity memory, which can realize 1000 sets of data storage functions.
  12. Purity measurement accuracy is 0.5% in the full range. It can be applied to the measurement of high concentration SF6 gas and 70% content SF6 gas.
  13. The best test flow area shows that the user can adjust the gas flow intuitively and quickly. Reduce test time.
  14. The air inlet is designed with a miniature self-sealing joint, and the air path to be tested will not leak when the air path is disconnected.
  15. It can expand USB communication, serial communication, wireless communication module, and realize the communication and printing functions of the upper computer. (optional)
  16. The gas path pretreatment function can be used to purify the test pipeline before the field test work, which shortens the test time. (optional)
  17. The instrument has a test gas recovery function to recover the sulfur hexafluoride measurement gas. Protect the natural environment. (optional)
Specifications
 
Measurement method Infrared Measurement Principle (NDIR series sensors)
Working environment -20ºC ~ +60ºC
Measuring range 0 ~ 100% SF6
Response time [90%] 60s
Accuracy ± 0.5%FS
Repeatability ± 0.5%
Resolution 0.01%
Display unit %
Gas flow rate 400 ~ 600ml/min
Flow rate display 0~1000mL import digital flowmeter
Simple gas pressure ≤1MPa
Environment humidity 90%RH
Measurement value influence No effect of pressure and flow
Power supply AC 220V±10%, 50Hz / DC Battery inside can work at least 8 hours
Dimension 395*295*155mm
Weight about 2kg.

HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
HVHIPOT SF6 Gas Purity Tester Purity Analyzer GDP-311IR
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier