HVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF

Product Details
Customization: Available
After-sales Service: yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF
  • HVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF
  • HVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF
  • HVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF
  • HVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF
  • HVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF
Find Similar Products

Basic Info.

Model NO.
VLF-84
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Peak voltage
80kV
Test frequency
0.1Hz, 0.05Hz and 0.02 Hz (selectable)
Transport Package
Standard Plywood Case
Specification
ISO9001
Trademark
HV HIPOT
Origin
Wuhan, China

Product Description

Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF




General introduction

Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages.

Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test.

 
Aspects DC Power Frequency Variable Frequency 0.1Hz
Equivalency poor good good good
Insulation Damage strong slight slight slight
Operation Safety relatively low relatively low relatively low high
Wiring Difficulty complicated complicated most complicated simple
Volume smallest largest large small

In fact VLF test is the substitute for power frequency test. It is suitable for testing electrical equipment with large capacitance(like power cable, power capacitor, motor and generator).


Description

The new generation of VLF series 0.1Hz VLF AC Hipot Test Set developed by HV Hipot adopts "Smart Quick" intelligent power test system (Soft No. 1010215, trademark registration number 14684781), HVHIPOT company introduced the latest international power electronic components and the latest ARM7 microcontroller technology, further reducing the size and weight of the equipment. The operation is easier and the performance is more stable.


Features
 
1. Advanced technology adopts digital frequency conversion technology, fully automatic microcomputer control, voltage boost, step-down, measurement, protection, etc.
 
2. Control part and High-voltage part adopt an integrated structure design, and only a high voltage wire and ground wire are needed to connect to the tested product without the intermediate connection wire.
 
3. Trolley-style design is convenient for transportation in various working environments, and its small size and light weight are very conducive to outdoor operations(80kV).
 
4. Over-voltage protection and over-current protection. Action time is no longer than 10ms.
 
5. The control unit and the booster are connected at low voltage, with photoelectric isolation control, safe and reliable to use.
 
6. Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.
 
7. Capacitive touch screen, LCD graphic display, automatic storage and printing.
 
8. 0.1Hz, 0.05Hz and 0.02Hz can be chosen, which ensures a wide test range.


Specifications
 
  1. Peak voltage: 30kV or 80kV
  2. Test frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)
  3. Maximum load capacity: 1.1μF@0.1Hz
                          2.2μF@0.05Hz
                          5.5μ[email protected]
     4. Measurement accuracy: 3%.
     5.Voltage peak value error: 3%.
     6. Voltage waveform distortion: 5%.
     7. Working environment: indoor or outdoor; -10ºC-+40ºC; 85%RH
     8. Fuse: 8A (30kV), 20A(80kV)
     9. Power supply: 220V ±10%, 50Hz ±5% (If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW, frequency 50Hz, voltage 220V±5%.)
   10. Capacitance of the tested object shall not exceed the max. rated capacitance of the instrument. The max. capacitance please see below table.
 
Model Rated voltage Load capacitance Power fuse Structure & Weight
VLF-34/1.1 30kV 
(peak value)
0.1Hz, ≤1.1µF 8A One piece: 30kg
0.05Hz, ≤2.2µF
0.02Hz, ≤5.5µF
VLF-84/0.5 80kV 
(peak value)
0.1Hz, ≤1.1µF 20A Control unit: 4kg
Booster: 50kg
0.05Hz, ≤2.2µF
0.02Hz, ≤5.5µF


HVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLFHVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLFHVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLFHVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLFHVHIPOT Very Low Frequency 0.1Hz 0.2Hz AC Hipot Test Set VLF







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier