Suppliers with verified business licenses
Rated output | Frequency error: <±0.01Hz Phase error:<±0.2° Waveform distortion: <±0.3% (fundamental wave) Time error: <40µs Output frequency: 20~1000Hz |
|
Power voltage | Allowable range: AC220V±10%,50Hz±10% | |
Ambient temperature | Use range: 0~40ºC Storage range: -20~70ºC |
|
AC source | Current | 6 Phase current output (RMS): 0~30A/phase 3 Phase current output (RMS): 0~60A/phase 6 parallel current output (RMS): 0~180A Long-term allowable working value of phase current (RMS): 10A Allowable working time of 6 parallel current 180A: 10s Accuracy: <±0.2% Max. Output power of phase current: 300VA Max. Output power of 6 parallel phase current: 1000VA Harmonic frequency: 1~20 times |
Voltage | Phase voltage output (RMS): 0~120V Line voltage output (RMS): 0~240V Accuracy: <±0.2% Phase/Line voltage output power: 80VA/100VA Harmonic frequency: 1~20 times |
|
DC source | Current | Output range: 0~±10A/phase Accuracy: <±0.5% Max. Output load voltage: 20V |
Voltage | Phase voltage output amplitude: 0~±160V Line voltage output amplitude: 0~±320V Accuracy: <±0.5% Phase/Line voltage output power: 70VA/140VA |
|
Time measurement | Test range: 0.1ms~9999s Accuracy: <0.1mS |
|
8 Binary input | Idle contact: 1~20mA, 24V(DC) Electric potential contact: "0": 0 ~ +6V; "1": +11 V ~ +250 V |
|
4 Binary output | DC: 220 V/0.2 A: AC: 220 V/0.5 A | |
Dimension | 410mm ×360mm ×200mm | |
Weight | 23kg |
Suppliers with verified business licenses