| Accuracy level | 0.1% |
| Output voltage | 3*100V/57.7V Y 3*100V ; 3*380V/220V Y 3*380V |
| Regulating range | 0-120% consecutively adjustable |
| Regulating accuracy | better than 0.01% |
| Current range | 25mA, 0.1A, 1A, 5A, 25A, 100A |
| Regulating range | 0-120% consecutively adjustable |
| Regulating accuracy | better than 0.01% |
| Min.output current | 1mA (accuracy: <5%) |
| Output power | (voltage loop) GDYB-S3 3*50VA (current loop) GDYB-S3 3*150VA |
| Stability of output voltage, current and power: | ≤0.02%/120S PF=1 (Class 0.05) |
| Wave distortion of output voltage and current | ≤0.5% |
| Symmetry of three phase | better than 120°+0.3° |
| Frequency range | 45Hz-65Hz regulating accuracy: 0.01 Hz |
| Phase shifting range | -180.0°-180.0° regulating accuracy: 0.1° |
| Wave distortion of output voltage and current | ≤0.5% |
| Symmetry of three phase | better than 120°+0.3° |
| Frequency range | 45Hz-65Hz regulating accuracy: 0.01 Hz |
| Phase shifting range | -180.0°-180.0° regulating accuracy: 0.1° |
| Standard crystal oscillator stability | ≤10-7/s |