Customization: | Available |
---|---|
After-sales Service: | YES |
Warranty: | 1 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Accuracy level | 0.1% |
Output voltage | 3*100V/57.7V Y 3*100V ; 3*380V/220V Y 3*380V |
Regulating range | 0-120% consecutively adjustable |
Regulating accuracy | better than 0.01% |
Current range | 25mA, 0.1A, 1A, 5A, 25A, 100A |
Regulating range | 0-120% consecutively adjustable |
Regulating accuracy | better than 0.01% |
Min.output current | 1mA (accuracy: <5%) |
Output power | (voltage loop) GDYB-S3 3*50VA (current loop) GDYB-S3 3*150VA |
Stability of output voltage, current and power: | ≤0.02%/120S PF=1 (Class 0.05) |
Wave distortion of output voltage and current | ≤0.5% |
Symmetry of three phase | better than 120°+0.3° |
Frequency range | 45Hz-65Hz regulating accuracy: 0.01 Hz |
Phase shifting range | -180.0°-180.0° regulating accuracy: 0.1° |
Wave distortion of output voltage and current | ≤0.5% |
Symmetry of three phase | better than 120°+0.3° |
Frequency range | 45Hz-65Hz regulating accuracy: 0.01 Hz |
Phase shifting range | -180.0°-180.0° regulating accuracy: 0.1° |
Standard crystal oscillator stability | ≤10-7/s |
Indicating instruments class | Voltmeter and ammeter accuracy: level ±0.2% Phase meter accuracy: ±0.5° Frequency meter accuracy: ±0.01Hz |