GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch

HV Hipot Electric Co., Ltd.
  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • High Current Output: Delivers 500A in series or 1000A in parallel for primary current injection testing.
  • IP67 Waterproof Design: Engineering plastics box with IP67 rating ensures dust-proof and waterproof performance.
  • Portable & Durable: Lightweight design with damping features ensures safe transport and on-site usability.
  • Zero Start Safety: Built-in zero start function prevents damage from high current impulses during startup.
  • Precise Digital Display: LCD digital indicator displays output current and voltage with 1A resolution.
  • Synchronous Time Testing: Tests action time of objects synchronously with lock action time recording capability.
  • High Accuracy Grade: Features 1.0% accuracy with standard sine wave output and less than 5% distortion.
  • Multi-Calibration Support: Allows multiple calibrations to be series connected simultaneously to improve efficiency.

Product Images of GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch

GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch pictures & photos
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch pictures & photos
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch pictures & photos
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch pictures & photos
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch pictures & photos
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch pictures & photos
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
  • GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
  • GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
    GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
  • GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
    GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
  • GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
    GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
  • GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
    GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
  • GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
    GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
  • GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
    GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch

Find Similar Products

Product Description

I. General Information
 
GDSL-BX-200 Primary Current Injection Test Set, is mainly used for testing current transformer, motor protector, air switch, switch cabinet, circuit breaker, protection screen and etc.
 
 
II. Features
 
1. PVC panel, simple and neat.
2. With low power, big capacity autotransformer regulator and converter inside.
3. Quick connects, lock design, good current-through capability.
4. Built-in quick plug with high safety, to ensure reliable cable connection and improve test efficiency.
5. Current range can be changed, easy to read.
6. Engineering plastics box, dust-proof and waterproof, IP67 class.
7. Portable design, suitable for on-site testing.
8. Damping design, to ensure reliable transportation
9. Zero start function to prevent the test objects from damage caused by high current impulse. The equipment only can be started from zero.
10. Impulse selection function. The required current can be output directly without zero protection function when making quick-break testing for circuit breaker.
11. Accurate measurement. LCD digital indicator to display output current and voltage. The resolution of output current is 1A .
12. Output 0-50A AC current, suitable for over current quick break testing of secondary protection.
13. Action time can be tested synchronously.
14. More calibrations can be series connected at the same time to improve working efficiency .
15. Directly display primary current and secondary current, convenient for CT/PT turn ratios calibration test. (Optional)
 
 
III. Specifications
 
Power supply AC 220V 50Hz.
Output power 3kVA.
Output current 500A in series,1000A in parallel.
Output voltage 6V in series, 3V in parallel.
Current can be adjusted smoothly and continuously. The accuracy is 1.0%.
Output current is standard sine wave, waveform distortion is less than 5%.
Secondary injection current 50A
Output current RMS continuous adjustable.
The action time of test object can be tested, the lock action time is also can be recorded at the same time.
Test range 0.001S-999.999S, resolution 1ms, error: 0.005%, range: ±2digits
Duty Cycle 5mins ON, 10mins OFF.

GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV SwitchGDSL-BX-200 500A Primary Current Injection Test Set for HV SwitchGDSL-BX-200 500A Primary Current Injection Test Set for HV SwitchGDSL-BX-200 500A Primary Current Injection Test Set for HV SwitchGDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the maximum output current?
The device outputs 500A in series mode and up to 1000A in parallel mode.
Is the equipment waterproof?
Yes, it features an engineering plastics box with an IP67 rating, making it dust-proof and waterproof.
What is the duty cycle?
The duty cycle is 5 minutes ON and 10 minutes OFF.
Can it test action time?
Yes, it can test the action time of the test object synchronously and record the lock action time.
What is the accuracy grade?
The accuracy grade is 1, with an accuracy of 1.0% and waveform distortion less than 5%.
Is customization available?
Yes, ODM service is available for this product.
What is the power supply requirement?
The power supply requirement is AC 220V 50Hz.
What is the lead time for orders?
The average lead time is one month for both peak and off-season periods.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now