HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • Patented DC Frequency Attenuation: Uses patented technology to eliminate residual magnetism hazards effectively.
  • Single-Phase Degaussing Efficiency: Only degauss B phase to complete the whole work for three-phase transformers.
  • Fast and Effective Degaussing: Manual mode takes 4 mins, automatic over 90% effect per time.
  • Customizable Degaussing Current: Current options: 5A, 2A, 200mA, 5mA, with customization available.
  • Direct Cable Compatibility: Current lines of DC resistance testing can be directly used for easy matching.
  • Portable Field Design: Small size and light weight (5kg), most suitable for field testing.
  • Automatic Data Processing: Features automatic judgment and 16AD data collection and processing.
  • Wide Voltage Application: Suitable for 35kV and above, especially large capacity 330kV+ transformers.

Product Images of HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000

HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000 pictures & photos
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000 pictures & photos
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000 pictures & photos
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000 pictures & photos
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000 pictures & photos
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000 pictures & photos
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
  • HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
    HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
  • HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
    HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
  • HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
    HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
  • HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
    HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
  • HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
    HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
  • HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
    HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000

Find Similar Products

Product Description

Automatic Power Transformer Protection Demagnetization Tester GD8000



General Information

 
GD8000 power transformer degaussing instrument is to eliminate hazards of the residual magnetism after the DC resistance test of large power transformers. It can protect power transformer from inrush current impact, also has an extremely important role in safety commissioning.
Due to the inherent hysteresis of the ferromagnetic materials, after the transformer voltage ratio, DC resistance measurement, the residual magnetism will remain in the transformer core. When the transformer put into operation, the residual magnetism will make transformer core in half saturation and generate a large number of harmonics in excitation current, which will increase the reactive power consumption of transformers and may cause malfunction of relay. Therefore, we should do the degaussing work to ensure safe running before the transformer put into operation.


Features
  1. Using patented technology - DC frequency attenuation technique
  2. Three phases transformer, only degauss B phase to complete whole work
  3. Automatic judgment, 16AD data collected and processing function
  4. Degaussing mode is automatic and manual.
  5. Fast degaussing, no more than 4mins.
  6. Degaussing effect is obvious, automatic over 90%/time
  7. Current lines of DC resistance testing can be directly used, easily matched with DC resistance test
  8. Display the degaussing current, time and schedule.
  9. Suitable for 35kV and above power transformer and PT/CT, especially for 330 kV and above voltage level of large capacity transformer.
  10. Small size and light weight, most suitable for field testing.

Specifications
 
Degaussing current 5A, 2A, 200mA, 5mA (Can be customized)
Degaussing way Manual or Automatic mode.
Degaussing Maunal:4min/time, automatic 9min/time .(no need to consider voltage grade and capacitor)
Degaussing effect Over 90%/times 
Degaussing process 0-100% Automatic recording and erasing time
Working power AC220V±10%, 50Hz±1Hz
Temperature -25ºC - 50ºC, RH≤90%.
Weight 5kg (net weight) not including the connection wire

HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the purpose of the GD8000 tester?
It eliminates residual magnetism hazards after DC resistance tests, protecting transformers from inrush current and ensuring safe commissioning.
How long does the degaussing process take?
Manual mode takes 4 minutes per time, while automatic mode takes 9 minutes per time.
What is the degaussing effect efficiency?
The degaussing effect is obvious, achieving over 90% efficiency per time in automatic mode.
Can the degaussing current be customized?
Yes, the degaussing current can be customized. Standard options include 5A, 2A, 200mA, and 5mA.
What is the warranty period for this device?
The product comes with a 1-year warranty.
Is the device suitable for field testing?
Yes, it features a small size and light weight (5kg net), making it most suitable for field testing.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now