HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing

HV Hipot Electric Co., Ltd.
  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Images of HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing

HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing pictures & photos
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing pictures & photos
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing pictures & photos
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing pictures & photos
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing pictures & photos
HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
  • HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
  • HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
    HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
  • HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
    HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
  • HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
    HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
  • HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
    HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
  • HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing
    HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing

Find Similar Products

Product Description

HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing

I. General information

GDBT-300kVA/36kV is mainly to make no-load, load and induction voltage test, power frequency withstand voltage test and temperature rising test for 36kV, 300kVA and below distribution transformers.

The measurement part is controlled by single chip. Digital display, no-load and short circuit test data will be sampling by single chip at the same time.


II. Test Items
 

  1. 3-phase voltage RMS
  2. 3-phase current RMS
  3. 3-phase active loss
  4. 3-phase reactive loss
  5. 3-phase average voltage
  6. 3-phase voltage average value
  7. 3-phase current average value
  8. Total power
  9. No-load current percentage
  10. Impedance voltage percentage
  11. Frequency
  12. Power factor
  13. Induced voltage test
  14. Power frequency withstand voltage test
  15. Temperature rising test


III. Specifications

Transformer Power analyzer
  1. Voltage range: 0-100V, current measurement range 0.1-5A, accuracy 0.2%.
  2. Power U*I, accuracy 0.5%.
  3. Power factor 0.050-1.000, accuracy 0.3%
  4. Frequency 40-70Hz, accuracy 0.1%.
  5. Power P
  6. No-load current Io, %
  7. No-load loss Po
  8. Load loss Pk
  9. Impedance voltage Uk
  10. 3phase Power Pa (Pab), Pb, Pc (Pbc)
  11. Average line voltage Un
  12. Average current In.

DC Winding Resistance Tester (for HV side)
  1. Measure HV coil resistance. It also can measure continuously according to interval time.
  2. Test process is controlled by microcomputer, automatically finish self-calibration, constant current determination, data processing and resistance display.
  3. Output current: 10A, 2A, 500mA, 100mA
  4. Measuring range: 500μΩ-200Ω
  5. Resolution: 0.1μΩ
  6. Measuring accuracy: ± (0.2% of the reading+2digit)
  7. Power input: AC220V± 10%, 50±1Hz
  8. Environmental temperature: -10ºC-50ºC
  9. Environmental humidity: ≤85%RH
  10. It can make DC resistance measurement, as well as HV heating resistor measurement in temperature-rise test.

DC Winding Resistance Tester (for LV side)
  1. Measure LV coil resistance. It also can measure continuously according to interval time.
  2. Test process is controlled by microcomputer, automatically finish self-calibration, constant current determination, data processing and resistance display.
  3. Output current: 10A, 2A, 500mA, 100mA
  4. Measuring range: 500μΩ-200Ω
  5. Resolution: 0.1μΩ
  6. Measuring accuracy: ± (0.2% of the reading+2digit)
  7. Power input: AC220V± 10%, 50±1Hz
  8. Environmental temperature: -10ºC-50ºC
  9. Environmental humidity: ≤85%RH
  10. It can make DC resistance measurement, as well as LV heating resistor measurement in temperature-rise test.

Automatic Temperature Inspector
The PC on the test bench can read, record, and save test data automatically.
  1. Measurement range of resistor: 0-2000Ω
  2. Measurement range of temperature 0-200ºC 
  3. 16channel temperature sensor.
  4. With fast and efficient communication port, which shorten communication time greatly.
  5. Environment temperature support: 4pcs.

AC testing transformer
  1. Rated capacity: 10kVA
  2. Rated output voltage: 0-100kV.
  3. Rated output current: 0-100mA
  4. Rated input voltage: 0-400V
  5. Rated input current: 0-25A
  6. Working frequency: 60Hz

Frequency generator set
  1. Output voltage: 40-800V
  2. Rated capacity: 20kW
  3. Input voltage: 380V
  4. Output frequency: 180Hz ± 2%

After the generator is started successfully, the no-load residual magnetization voltage of the intermediate frequency generator does not exceed 40V. By adjusting the excitation, the output voltage is continuously adjustable within the range of not exceeding 40V to 800V.

40kVA 3-phase regulator (Inside the HV auxiliary cabinet)
  1. Capacity: 40kVA
  2. Input voltage: 400V
  3. Output voltage: 0-450V.

Intermediate transformer 30kVA (Inside the HV auxiliary cabinet)
  1. Rated capacity: 30kVA
  2. Rated input voltage: 0.4kV
  3. Rated output voltage: 3kV, rated output current 5.77A
  4. Withstand class 15kV, time 60s
  5. Impedance voltage is no more than 4%
  6. Meet the requirement of 24hours temperature rise test.
  7. Induced voltage test: it is considered at continuous time operation with 2times voltage with load.

High Precision CT
  1. Rated working voltage: 3kV/√3
  2. Withstand voltage: 3kV.
  3. Capacity: 5VA
  4. Measuring range: 5-200A
  5. Accuracy: class 0.05
  6. Turns Ratio 25, 10, 5/5A.

High Precision PT
  1. Rated working voltage: 3kV/√3
  2. Withstand voltage: 4kV
  3. Capacity: 1VA
  4. Accuracy: class 0.05
  5. Turns Ratio 3kV, 1.5kV/100V/√3.

HVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testingHVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testingHVHIPOT Customized GDBT-300kVA/36kV Transformer Test system with test bench for transformer testing

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time, one month, Off Season Lead Time, one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified Production Machines
Assembling Line, Testing Line
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now