HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • GB/T5654-2007 Compliant Design: Three-electrode structure eliminates stray capacitance and leakage effects for accurate results.
  • Stable SF6 Internal Capacitor: SF6 gas-filled capacitor ensures accuracy is not affected by ambient temperature or humidity.
  • Comprehensive Protection System: Auto-cuts off pressure on over-voltage/current/short-circuit and warns on sensor failures.
  • User-Friendly LCD Interface: Large-screen LCD with backlight, auto-test, and automatic storage/printing of results.
  • Versatile Voltage Settings: AC voltage 500~2200V and DC voltage 0~500V, continuously adjustable for diverse tests.

Product Images of HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C

HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C pictures & photos
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C pictures & photos
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C pictures & photos
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C pictures & photos
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C pictures & photos
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C pictures & photos
HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
  • HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
  • HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
    HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
  • HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
    HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
  • HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
    HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
  • HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
    HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
  • HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
    HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
  • HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C
    HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C

Find Similar Products

Product Description

I. General Information

GD6100C Automatic Precision Oil Dielectric Loss Tester, is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. The instrument intergrates with test oil cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. 
 
II. Feature
1. The test cell adopts the three-electrode structure according to national standard GB/T5654-2007, with electrode spacing 2mm, which can eliminate the effects of the stray capacitance and leakage on dielectric loss test results. The device is equipped with the oil drainage solenoid switch, and we can empty the test cell without removing it and rinse it with the test sample oil.
2. The instrument adopts the medium frequency induction heating, PID temperature control algorithm. This heating method has the advantages of non-contact between the test cell and the heating body, uniform heating, fast speed, convenient control, and strictly control of the temperature within error range of the preset temperature.
3. Internal standard capacitor is SF6 gas-filled three-electrode capacitance, and its capacitor dielectric loss and electrical capacity are not affected by ambient temperature, humidity etc, so that the instrument accuracy can be ensured even after prolonged use.
4. AC test power supply uses AC-DC-AC conversion, which effectively prevents the fluctuations in mains voltage and frequency from affecting the dielectric loss measurement accuracy. Even a generator, the instrument can work properly.
5. Perfect protection function.When there is over voltage,over current or high-voltage short circuit, instruments can quickly cut off pressure, and issues a warning message. When the temperature of the sensor failure or not connected, the instrument will also issue a warning message.
6. There is a temperature limiting relay in the medium frequency induction heating furnace. When temperature above 120 degrees, the instrument frees the relay and stops heating.
7. Convenient test parameter setting.Temperature setting range 0~125 degree, AC voltage setting range 500~2200V, DC voltage setting range 0~500V.
8. Using of large-screen LCD display, with backlight and clear display. Friendly interface, simply follow the Chinese menu prompt, enter the command, the instrument can be automatically tested. And automatically store and print test results.
9. Built-in real-time clock, the test date and time may be saved, displayed and printed with the test results.
10. Calibration functions of cleaned dry cell. The measurement of dry cell's capacitance and dielectric loss factor can determine its cleaning and assembly conditions. The calibration data is automatically saved and so that it facilitates the calculation of relative permittivity and DC resistivity.
 
III.Specification 
Voltage supply : AC 220V±10%
Power frequency : 50Hz/60Hz ±1%
Measuring range:
Capacitance: 5pF~200pF
Relative Permittivity :1.000~30.000
Dielectric loss factor : 0.00001~100
DC Resistivity : 2.5MΩm~20TΩm
Measuring accuracy:
Capacitance : ± (1% of reading+0.5pF)
Relative Permittivity : ±1% of  reading
Dielectric dissipation factor : ± (1% of  reading+0.0001)
DC Resistivity : ±10% of reading
Resolution :
Capacitance : 0.01pF
Relative capacitivity:  0.001
Dielectric dissipation factor : 0.00001
Measured temperature range : 0~125 degree
Temperature measurement error : ±0.5 degree
AC Test Voltage (RMS) : 500~2200V Continuously adjustable, frequency 50Hz
Test Voltage DC : 0~500V Continuously adjustable
Power consumption: 100W
Ambient temperature:0~40 degree
Relative humidity(RH):<75%
Dimensions : 500×360×420
Total weight : 22Kg

HVHIPOT Automatic Precision Oil Dielectric Loss Tester GD6100C

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the measuring range for capacitance?
The capacitance measuring range is 5pF to 200pF with a resolution of 0.01pF.
Does the instrument maintain accuracy in varying environments?
Yes, it uses an SF6 gas-filled internal standard capacitor that is not affected by ambient temperature or humidity.
What safety protections are included?
It features protection against over-voltage, over-current, and high-voltage short circuits, plus warnings for sensor failures.
How is the test data stored and printed?
The instrument automatically stores and prints test results, including date and time via its built-in real-time clock.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.