Automatic Transformer Calibration System (GDHT)

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDHT
Quadrature Component
0.001~700.0 Resolution:0.001
Admittance(Ms)
0.0001~20.0 Resolution:0.0001
Cophase Component
ΔX=±(X×2%+Y×2%±dx)
Overall Dimension
(L 375×w 330×h 140)mm³
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030841000
Production Capacity
500PCS/Year

Product Description

GDHT-6 Automatic Transformer Calibration System is used to test the technical performance of on-site or laboratory voltage PT and current CT.


Features

1. Easy operation, high automation.
2. Menu management, data input simple and convenient.
3. 320X240 LCD, background light, easy to use.
4. Can display dial indicator, ratio error and angular error.
5. Control modes: By PC, auto and manual.
6. Auto switching the load cases to reduce the human operation and reduce the error.
7. Auto judge the polarity and turns ratio error.
8. PC software can show the error curve.
9. PC software with function of virtual opening.
10. Solve S level measuring problem.
11. Switching measuring range automatically.
12. Solve unstablity problem of the Rc phase-shift circuit
13.light weight, convenient for outdoor operation.



Specifications
 
Power supply AC220V±10% 50Hz±10%
Working environment Temperature 0~+40 degree
Relative humidity ≤85%(25 degree)
Regulator control output capacity  7kVA(250V 30A)(Extension by option)
Regulator precision Better than 0.04V
Measuring range Cophase component(%):0.0001~200.0 Resolution:0.0001
Quadrature component:0.001~700.0   Resolution:0.001
Impedance(Ω):0.0001~20.0    Resolution:0.0001
Admittance(ms):0.0001~20.0    Resolution:0.0001
Basic error Cophase component:ΔX=±(X×2%+Y×2%±Dx)
Quadrature component:ΔY=±(X×2%+Y×2%±Dy)
"X"\"Y"__Value show on instrument
"Dx,Dy"__Quantization error of instrument
Dial indicator:1.5
Output current and voltage:2
Woking range Current (1%-149%)In (In =5A)
(5%-149%)In (In =1A)
Voltage (5%-149%)Un (Un =100V,150V,100V/)
(5%-149%)Un (Un =100V/3)
Working load Current:TO-TX<0.12Ω cosΦ=1
Voltage:a-x<0.25VA (100V)
Polarity error More than 5% of rated working current(voltage),error over than 180%, such as polarity.
Turns ratio error More than 5% of rated working current(voltage),error over than 30% but less than 180%, shall display turns ratio error.
Insulation and HV test Terminal TX connect with( )
Power sockets shell can withstand 1.5kV,1min HV
Overall dimension (L 375×W 330×H 140)mm³
Weight 10kg