GDPQ-300H Power Quality Analyzer is a portable device of testing and analyzing power system operation quality. It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis. Meanwhile, it equips with data analysis software, by which the measure data can be uploaded to PC.
Main specifications
| Input | |
| Voltage measurement range | 0-800V , auto shift |
| Current measurement range | CT: 5A/25A (standard) 100A/500A (optional) 400A/2000A (optional) |
| Phase angle measurement range | 0~359.99° |
| Frequency measurement range | 45~55Hz |
| Voltage channel | 3 channel (UA, UB, UC) |
| Current channel | 3 channel (IA, IB, IC) |
| Maximum harmonic analysis times | 63 times. |
| Maximum continuous storage period of 1 minute interval | 18 months. |
| Accuracy | |
| Electrical parameter measurement section | |
| Voltage | ±0.1% |
| Frequency | ±0.01Hz |
| Current, power | ±0.5% |
| Phase | ±0.2° |
| Power quality part | |
| The fundamental voltage tolerance error | ≤0.5%F.S |
| Fundamental current tolerance error | ≤1%F.S. |
| Measurement error of phase difference between fundamental voltage and current: | ≤0.2° |
| Harmonic voltage content measurement error | ≤0.1% |
| Harmonic current content measurement error | ≤0.2% |
| Three-phase voltage imbalance error: | ≤0.2% |
| Voltage deviation error | ≤0.2% |
| Voltage variation error | ≤0.2% |
| Working temperature | -10ºC~ +40 ºC |
| Charging power | AC 220V , 45Hz-55Hz |
| host power consumption | ≤ 3VA |
| the maximum working time of the battery | ≤ 10 hours |
| Insulation | (1) The insulation resistance of the voltage and current input terminals to the casing is ≤100MΩ. (2)The working power input end is subjected to a power frequency of 1.5KV (effective value) between the outer casings, and it takes 1 minute to test. |
| Dimension | 258mm *158mm *58mm |