• Online Partial Discharge Monitoring System
  • Online Partial Discharge Monitoring System

Online Partial Discharge Monitoring System

Type: Universal Testing Machine
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Control: Computer Control
Weight: 0-100Kg
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDPD-GIS
Power Source
AC220V
Bandwidth limit
100K-100MHz analog input bandwidth optional
Sampling rate
100MS/s single sampling
Trigger mode
external trigger or power trigger
Communication Protocol
TCP/IP Network Protocol
Transport Package
Standard Export Wooden Box
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
HS Code
9030849000
Production Capacity
10000 PCS/Year

Product Description

 Online Partial Discharge Monitoring System GDPD-GIS

General Information

Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely, it will cause serious damage to the grid. Partial discharge fault is a common fault type of GIL/GIS. It is necessary to use GIS partial discharge online monitoring and fault location system to perform real-time online monitoring of GIL/GIS partial discharge signals and analyze and process the measured data and real time give comprehensive judgment of insulation status. Then repair schedule can be arranged according to the monitoring results to avoid major grid accidents caused by equipment failure and to ensure the normal operation of the system with minimum maintenance cost.

There are many reasons for the deterioration of the dielectric medium, such as ionization corrosion caused by a strong electric field for a long time, insulation wear caused by mechanical high-frequency vibration, aging decomposition of the medium caused by thermal effects, and moisture insulation. The dielectric medium is degraded, and the performance is degraded so that the dielectric breakdown has a development process, which makes the on-line monitoring of insulation practical and effective. The system uses Smart Quick software developed totally by HVHIPOT. It uses advanced high-speed DSP digital processing technology and software. The processing technology makes our monitoring system fast and accurate, which is the most economical and reliable solution for the online monitoring system of GIS.


Principle

Through installing UHF sensor on the key components of GIL/GIS, to collect 500MHz-1500MHz electromagnetic wave signal excited by the partial discharge of GIL/GIS in real time. It also collects feature quantities such as amplitude (Q), phase (Φ), frequency (N), and cycle sequence (t) of the partial discharge pulse signal that reaches the trigger condition by detection frequency reduction circuit, high speed sampling circuit and data processing buffer circuit. Event files are generated and uploaded to upper computer expert diagnosis system, to perform event map establishment and monitoring equipment insulation state analysis.


Technical Specifications

PD sensor specifications
 
Index Name Value Unit Remark
Environment Working temperature -25 ~ +65 ºC  
Working humidity < 95% /  
Performance Sensitivity -80(internal)
-75(external)
dbm  
Measurement bandwidth 300-2000 MHz  
Measurement accuracy 0.1 dB  
Average equivalent height > 10 mm  
Over-voltage protection Yes    
Signal interface N type RF terminal /  
Appearance Material 6061 Aluminum alloy (indoor)
304 Stainless steel (outdoor)
/  
Size Customized mm Customized
Waterproof Yes    
Lifetime > 50 Year  
Voltage class All voltage ranges are suitable /  

IED unit (PD collector)
 
Index Name Value Unit Remark
Working power supply and environment Power input AC 120-240 V  
Power consumption < 30 W  
Working temperature -25 -- +65 ºC  
Working humidity < 95% /  
Performance Self-checking function Yes / Self-checking after startup
Sensor Built-in or external /  
Bandwidth 300--1500 MHz  
Measurement range -80-- -20 dBm  
Measurement accuracy 0.1 dB  
Sensitivity -80 dbm  
Channel 4-16 pcs  
Synchronous scan channel All channels /  
Sampling rate ≥100 MHz  
Refresh rate ≤ 1 s  
Sampling mode 24h continuous /  
Sampling time coverage 100%    
Discharge type identification 5types above    
Monitoring content Discharge amplitude(Q), Phase(Φ), Times(N), Discharge rate /  
PD fault location Yes /  
Synchronization signal Power supply or other /  
Noise cancellation Yes /  
Over-voltage protection Yes /  
Signal input interface N type RF terminal /  
Communication interface RJ45, Fiber optics SC or ST /  
System performance Cabinet 2U/19inch plug-in case.
Or outdoor hang-type(304 stainless steel) For option
   
Lifetime 20 year  
Voltage class All voltage ranges are suitable /  
Extension Max. 1000pcs / Distributed networking
Test condition EMC test Pass /  
System performance test Pass /


Online Partial Discharge Monitoring System
Online Partial Discharge Monitoring System
Online Partial Discharge Monitoring System
Online Partial Discharge Monitoring System
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now