Basic Info.

Model NO.
GDLD-313IR
Type
Non-Dispersive Infrared Analysis
Sensitivity
0.01ppm/0.1ppm/1ppm
measurement range
0-50ppm, 0-1000ppm, 0-10000ppm
Principle
NDIR
Transport Package
Plywood Case
Specification
ISO
Trademark
HV HIPOT
Origin
Wuhan, China

Product Description

GDLD-313IR SF6 Gas Leakage Detector (NDIR series)

GDLD-313IR SF6 Gas Leak Detector is an infrared-type leak detector(NDIR technology). It is a color OLED display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point, and yearly leakage rate qualitatively and quantitatively. It's a good device suitable for the power supply department, installation and overhaul unit, and power test institute.


Application
 
  1. High Voltage Switch Equipment
  2. Rotor vane of helicopter
  3. Gas transmission system
  4. To detect fire extinguisher
  5. Ventilation efficiency research of buildings
  6. To detect danger
  7. Storage tank


Advantages
 
  1. No radiation.
  2. No need to replace high-pressure high pure argon gas regularly.
  3. No need to approach high-pressure gas.
  4. No need to replace sensors regularly, cost-effective.
  5. Stable performance, low maintenance cost. No need to make linear calibration every year.
  6. No effect by moisture and environmental pollution.
  7. High sensitivity, up to 0.01ppmv.
  8. Detection speed <1s
  9. When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.


Features
 
  1. Qualitative and quantitative detection of leakage of SF6 electrical equipment.
  2. Zero function of ambient SF6 gas concentration.
  3. It can accurately locate the leak point of SF6 gas electrical equipment.
  4. Multi-parameters status on the same screensuch as SF6 concentration value, temperature and humidity value, battery indication, time, and diaphragm pump.
  5. Fast test speed, the data stability state can be achieved in 2s, and the data repeatability is good.
  6. With temperature and pressure compensation, it can perfectly compensate the gas concentration under different temperature and pressure environments.
  7. Using non-dispersive infrared (NDIR) technology, imported the world's top brand sensors from Germany.
  8. Only response to SF6 gas and does not respond to any other gas, and there will be no false alarms.
  9. Non-gas contact measurement performance guarantees no sensor poisoning at any concentration.
  10. OLED display.
  11. Built-in Lithium battery.
  12. User-defined alarm with sound and light.
  13. High sensitivity and good stability.
  14. Fast measurement speed, time is up to 3s.
  15. Temperature and pressure compensation.
  16. Only response for SF6 gas, not for other gas.
  17. Small size, easy to carry, suitable for on-site working.
  18. With gasbag non-slip straps, more comfortable to carry.
  19. Super-light aluminum with a full shielding shell.
  20. The external package uses engineering plastic, and with waterproof, and dust-proof.
  21. The data is stored in the form of concentration data plus detection time, which is convenient for the staff to accurately recall the required data. Can store more than 8000 sets of detection data values.
  22. It can store, view, and delete historical data and alarm records locally.


Specifications
 
Measuring principle Non-dispersive infrared sensor (NDIR)
Measuring range 0-50PPmv, 0-1000PPmv, 0-10000PPmv (optional)
Measurement resolution 0.1PPmv or 0.01PPmv
Accuracy ±2%FS 
Repeatability error ≤±1%
Response time 1s
Recovery time 3s
Long-term stability (span) ≤±20 ppm, over 1000 hours
Long-term stability (zero) ≤±20 ppm, over 1000 hours
Sampling method pump suction type, flow rate up to 1.5L/min
Zero shift ≤±1%(F.S/year)
Linear error ≤±1%
Display mode Colorful touch screen, Incell display technology
Battery Removable and replaceable, a single battery can continue to work for more than 4 hours, and wireless battery life can be achieved by battery replacement
Peak current <500mA
Average power <2W
Use air pressure 800---1150hPa
Environmental working humidity 0---95% RH (no condensation)
Storage temperature -20~+60ºC
Operation temperature -20~+50ºC
Sampling mode Built-in electromagnetic diaphragm pump, automatic slot-in type, flow up to 1L/min
Working voltage 220VAC±10%,50Hz Or Built-in Li-battery
Dimension 245×125×140mm
Weight about 1.5kg

HVHIPOT SF6 Gas Leak Detector Infrared Method Handheld DetectorHVHIPOT SF6 Gas Leak Detector Infrared Method Handheld DetectorHVHIPOT SF6 Gas Leak Detector Infrared Method Handheld DetectorHVHIPOT SF6 Gas Leak Detector Infrared Method Handheld Detector
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now