• AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure
  • AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure
  • AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure
  • AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure

AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure

Display Type: Digital Only
Certification: ISO
Input: 110V or 220VAC, ±10%, single phase
Frequency: 47-63Hz
Fuse: 4A/250VAC
AC withstand test: Rated output: 5kV AC
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GD9850A
Output waveform
Sine wave, 1.3<crest factor<1.5
Upper limit setting of leak current
Range: 0.01-12.00mA
DC withstand voltage test
Rated output: 6KV DC
Upper limit settin of DC leak current
range: 0.01-6.00mA
Slow rising time
Range: 0.1-999.9S
Test time
Range: 0.5-999.9S, 0 is continuous testing
Transport Package
Wooden Box
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030332000
Production Capacity
10000 Pieces/Year

Product Description

Product Description

The AC Insulation Tester is electric safety device. It is neat and compact structure with mature technology. It is widely used for household appliance, instrument and components etc.



Features
  • It has the functions of pass/fail determine, alarm, testing time automatic control.
  • Easy operation, small size.
  • With high speed of over-current cut-off.

Specifications
 
Input Voltage: 110V or 220VAC, ±10%, single phase
Frequency: 47-63Hz
Fuse: 4A/250VAC
AC withstand test Rated output: 5kV AC
Output frequency 50Hz or 60Hz, for option
Output waveform Sine wave, 1.3<crest factor<1.5
Upper limit setting of leak current Range: 0.01-12.00mA
Resolution: 0.01mA
Accuracy: ±(2% of setting value+2digit)
Lower limit setting of leak current Range: 0.00-12.00mA
Resolution: 0.01mA
Accuracy: ±(2% of setting value+2digit)
DC withstand voltage test Rated output: 6KV DC
Upper limit setting of leak current Range: 0.01-6.00mA
Resolution: 0.01mA
Accuracy: ±(2% of setting value+2digit)
Lower limit setting of leak current Range: 0.00-6.00mA
Resolution: 0.01mA
Accuracy: ±(2% of setting value+2digit)
Voltage setting Range:  0-5000V AC
0-6000V DC
Resolution: 1V
Accuracy: ±(2% of setting value+5V)
Voltage stability ±(1% of setting value+5V)
Slow rising time Range: 0.1-999.9S
Resolution: 0.1S
Accuracy: ±(0.1% of setting value+0.05S)
Test time Range: 0.5-999.9S, 0 is continuous testing
Resolution: 0.1S
Accuracy: ±(0.1% of setting value+0.05 S)
Arc detection Range: class 1 to class 9 can be set, 0 is non-detection arc status
Voltage display Range: 0-5.00KV AC
0-6.00KV DC
Resolution: 0.01KV
Accuracy: ±(3% of display value+3digit)
Current display Range: 0.01-12.00mA AC
0.01-6.00mA DC
Resolution: 0.01mA
Accuracy: ±(2% of display value+3digit)
Insulation resistance test Rated output: 1000V DC
Voltage setting Range: 500 - 1000V DC
Resolution: 100V
Accuracy: ±(2% of setting value+5V)
Voltage display Range: 0.50KV - 1.00KV DC
Resolution: 0.01KV
Accuracy: ±2% of display value
Resistance display Range: 1.000 - 2000MΩ
Accuracy: ±(5% of display value+3digit) (1-1000MΩ)
±(10% of display value+3digit)(1000-2000MΩ)
Upper limit setting of resistance 0-2000MΩ, 0 is non determination
Lower limit setting of resistance 1.0-999.9MΩ
Delay time of determination Range: 0.8 - 999.9 S, 0 is continuous determination
Resolution: 0.1S
Accuracy: ±(0.1% of display value+0.05 S)
Dimension 326x102x380mm
Weight 9kg


AC/DC Breakdown &amp; Insulation Resistance Tester/Testing Equipment With Compact Structure
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.