HV HIPOT GD-4134E Handheld  Cable Depth Path Detector for Underground Metal Pipeline

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HV HIPOT GD-4134E Handheld  Cable Depth Path Detector for Underground Metal Pipeline
  • HV HIPOT GD-4134E Handheld  Cable Depth Path Detector for Underground Metal Pipeline
  • HV HIPOT GD-4134E Handheld  Cable Depth Path Detector for Underground Metal Pipeline
  • HV HIPOT GD-4134E Handheld  Cable Depth Path Detector for Underground Metal Pipeline
  • HV HIPOT GD-4134E Handheld  Cable Depth Path Detector for Underground Metal Pipeline
  • HV HIPOT GD-4134E Handheld  Cable Depth Path Detector for Underground Metal Pipeline
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
GD-4134E
Test Mode
Various Frequency Method
Usage
Cable Test
Test Region
Forming Cable
Cable Type
Shielded
Power
Electricity
Certification
ISO
Customized
Non-Customized
Color
Orange
Active detection frequency for pipes
577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz,
Power frequency passive detection freque
50Hz/250Hz(user configurable).
RF passive detection frequency
577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz,
Pipe detection mode
Wide peak method, narrow peak method, sound Valley
Display
3.5-inch color LCD
Battery
7.4V DC 3400mAh rechargeable lithium battery
Transport Package
Standard Wooden Package
Specification
ISO, SGS
Trademark
HV HIPOT
Origin
Wuhan China
Production Capacity
2000PCS/Year

Product Description

GD-4134E Cable Testers & Cable Identifier
Product Description

GD-4134E Cable Identifier is a path detection instrument with strong comprehensive performance. It has multiple functions such as pipeline path detection, cable identification, pipeline grounding fault detection etc. The instrument consists of a transmitter, a transmitting current clamp, a receiver, a receiving flexible current clamp, a connecting test line, a stethoscope, an A-frame (optional), and RTK (optional).
 

Features

  1. Multiple detection modes: classic positioning mode, wire cruise mode, signal curve mode.
  2. Classic positioning mode: compass, direction and signal amplitude display, intuitive display of the left and right directions of the pipeline.
  3. Wire cruise mode: 360°all-round pipeline path indication, continuous display of depth, current and relative position of pipeline. The interface is simple and intuitive, and can be operated without experience.
  4. Signal curve mode: can display historical signal strength curves, and find the cable location by observing the changes in signal strength curves at different locations.
  5. Current direction determination (partial frequency), by calibrating the current direction, eliminating interference from adjacent lines and preventing tracking errors.
  6. Built-in sweep frequency test function, users can select the appropriate signal frequency for pipeline measurement through the sweep frequency results to avoid co-frequency interference.
  7. Fully digital high-precision sampling and processing: stable and reliable, ultra-high sensitivity, extremely narrow receiving passband, strong anti-interference ability, and can fully suppress the power frequency and harmonic interference of adjacent running cables and pipelines.
  8. Ground fault search (optional function): The transmitter transmits the positioning signal to the faulty cable. The A-frame (optional accessory) can be used to locate the ground fault location point of the pipeline, and the arrow indicates the positioning direction.
  9. Multiple detection frequencies: 12 active detection frequencies and 4 passive detection frequencies.
  10. Multiple signal output modes of the transmitter: direct connection output, clamp coupling output, radiation induction.
  11. Transmitter digital amplification power output, fully automatic impedance matching, and fully automatic protection.
  12. The instrument has a built-in high-brightness light under it for easy night operation.
Cable identification: It is designed to solve the technical problems of cable identification for power cable engineers and cable workers. It can be used to identify live cables and power-off cables. Users can accurately identify a target cable from multiple cables through the instrument to avoid serious accidents caused by mistaken sawing of live cables. When identifying cables, 10 cables can be pre-calibrated at the transmitter end, and then received and identified at the remote end, which greatly saves the time of engineers for round-trip calibration operations and improves work efficiency. Cable identification is successful and marked with √, and non-target cables are marked with ×, which can quickly and automatically identify the target cable. This function is realized by the cooperation of the signal transmitter, receiver, signal transmission clamp, connecting test line, flexible clamp and stethoscope. The stethoscope can be used when it is inconvenient to use the clamp.

Signal transmitter: used for pipeline path detection, cable identification and insulation resistance testing. The device can add identification signals to the target cable through direct output, caliper coupling, induction method, etc. The signal has 12 different pulse signals of 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10kHz, 33kHz, 66kHz, 82kHz and 201kHz to choose from. The maximum signal output power is 10W, and 10 gears are adjustable to adapt to different application environments, making pipeline detection and cable identification more accurate and reliable. The instrument has a built-in high-power rechargeable lithium battery, automatic impedance matching, and full-automatic protection. The transmitter adopts an integrated special tool box design, and its box can withstand a pressure of about 200kg. The host has a 5.4-inch color LCD display, which dynamically displays the signal output status and battery usage in real time.

Transmitter clamp: suitable for clamp coupling method. The transmitter clamp couples the signal emitted by the transmitter to the target cable. The jaw size is Φ150mm. The transmitter clamp is directional, and the transmission signal flows in from the direction indicated by the arrow on the transmitter clamp.

Receiver: used for pipeline path detection, cable identification and ground resistance testing. It has multiple built-in shielded 3D antennas, which can effectively identify 12 different pulse coded current signals of 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10kHz, 33kHz, 66kHz, 82kHz and 201kHz generated by the transmitter. It can also identify 50Hz and 250Hz power frequency signals and RF signals with center frequencies of 33kHz and 82kHz. Using a 3.5-inch color LCD screen, it can dynamically display 360° all-round pipeline path indication, depth, current and relative position of pipelines in real time.
A-frame (optional): A-shaped voltage signal sensor specially used for locating ground faults in direct buried cables. The two probes or coils of the A-frame can accurately receive the step voltage signal emitted by the transmitter. After transmitting it to the receiver for data analysis, the cable ground fault point can be accurately located. The probes or coils are designed to be independently interchangeable. The probes are suitable for muddy ground, and the coils are suitable for cement roads that cannot be directly inserted into the ground. The A-frame lead-out line is designed with an aviation socket, which is connected to the receiver with an aviation plug cable. It can be disassembled at will and is compatible with an independently designed handle, so that the A-frame can work independently of other functions.

Flexible current clamp: used for cable identification. This current clamp is a Rogowski coil with excellent transient tracking ability. It can quickly identify the pulse width frequency signal generated by the transmitter and is suitable for thick cables or irregularly shaped conductors. The inner diameter of the jaws is about 200mm, and it can clamp cables below Φ200mm. It is not necessary to disconnect the measured line. Non-contact measurement is safe and fast.
Stethoscope: used for cable identification. Similar to the shape of a mouse, it can quickly sense and identify the current signal in the transmitter or cable. The arc sensor design fully fits the cable surface. With the transmitter and receiver of this product, it can realize most of the functions of the flexible current clamp and can replace the flexible current clamp for cable identification in most occasions. When using it, just keep the stethoscope close to the cable to be tested along the direction of the cable. It is suitable for occasions where it is inconvenient to use a flexible current clamp for testing.

Special reminder: When identifying power-off cables: it is strictly forbidden to connect to live cables. Live cable identification is only applicable to three-core armored cables. When identifying, the transmitting clamp and the receiving clamp cannot be mixed, and the direction of the input signal must be consistent.
 
Product Parameters

 

Transmitter
Function Multiple frequency signal transmission methods
Power Supply 11.1V DC 12800mAh rechargeable lithium battery
Output Method Direct connection mode, clamp coupling mode, induction mode
Output Frequency 577Hz,640Hz,1280Hz,2.56kHz,3.20kHz,4.09kHz,8.19kHz,10kHz,33kHz,66kHz,82kHz,201kHz
Output Power 10W max, 10 levels adjustable
Impedance Fully automatic real-time impedance matching and protection function
Direct Output Voltage  150Vpp max
Circuit Protection With overload and short circuit protection
LCD 5.6-inch LCD color screen
Dimension Approximately 320mm (length)*275mm (width)*145mm (height)
Weight Transmitter weight about 3.85kg; Transmitter clamp weight about 1.18kg
Charger DC 12.6V 2A
Transmitter Clamp Size 297mm×194mm×39mm
Transmitter Clamp Inner Diameter φ150mm
Transmitter Clamp Wire Length 3m
Test Wire Red test line 3m, black test line 3m
Connection Interface 1*Type-B USB port (for firmware upgrade)
1*DC charging port
1*signal transmitter clamp connection socket
2*direct test line interface
Pressure-resistant The transmitter adopts an integrated special tool box design, and the box can withstand a pressure of about 200kg
Withstand Voltage AC 3700V/rms (Between the top and bottom of the instrument case)
Electromagnetic Characteristics IEC61326(EMC)
Safety Compliance IEC61010-1(CAT III 300V,CAT IV 150V,pollution level 2)
 
Receiver
Function Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, pipeline grounding fault detection.
Power Supply 7.4V DC 3400mAh rechargeable lithium battery
Input method Built-in receiving coil, flexible caliper, earphone
Receiving Frequency Active detection frequency: 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10kHz, 33kHz, 66kHz, 82kHz, 201kHz
Power frequency passive detection frequency: 50Hz, 250Hz
RF passive detection frequency band: center frequency is divided into 33kHz, 82kHz
Pipeline Detection Mode Wide peak method, narrow peak method, sound valley method
 Pipeline Detection Display Classic positioning mode, wire cruise mode, signal curve mode
Pipeline Detection Range  Direct connection method: generally can reach cable length of 0~20 kilometers, mainly determined by ground resistance, cable resistance and cable buried depthgenerally can reach cable length of 0~10 kilometers, mainly determined by ground resistance, cable resistance and cable buried depth
Induction method: suitable for cables buried less than 2m.
Depth and Current Automatically read cable depth and current value
Pipeline Measurement Depth 0~20m
Depth Accuracy Planar position precision positioning accuracy: center axis position of target cable or pipeline:
±5% (buried depth 0~3m), ±10% (buried depth 3m~20m)
True or False Tips Eliminate interference from adjacent cables. When measuring adjacent cables, the measurement of adjacent cables can be distinguished based on the different signal strengths and measured current phases of the adjacent cables. In the process of tracing the cables, observe the phase dial and pointer direction to distinguish the measured cable from the adjacent cables.
Sound Indicator FM tone that varies with signal strength
Anti-interference Ability Extremely narrow receiving frequency band, unique digital processing method, can fully suppress the power frequency and harmonic interference of adjacent running cables and pipelines
Interference Distance When using the coupling method and the induction method, the transmitter will generate interference within a short distance. The interference distance is related to the transmission power and frequency. The greater the power and the higher the frequency, the stronger the interference.
The minimum distance at which the receiver is not interfered by the transmitter often needs to be determined by experiment:
Pipeline detection: 5m away for the coupling method and 20m away for the induction method can be confirmed as no interference
Cable identification: 2~5m away for the coupling method can be confirmed as no interference
Cable Identification Identification method: flexible clamp intelligent identification, stethoscope identification;
Number of calibrable cables: 1 to 10;
Calibration value: The current percentage of the receiving signal and the transmitting signal is between 75% and 135% of the calibration value, which is one of the conditions for successful identification;
Directionality: The transmitting clamp, the receiving clamp and the loading signal must be in the same direction, which is one of the conditions for successful identification.
Cable Identification Detection Range Direct connection method: can identify signals with a loop resistance of 0Ω~8kΩ (generally can reach a cable length of 0~20 kilometers, mainly determined by the ground resistance and cable resistance)
Coupling method: can identify signals with a loop resistance of 0Ω~1kΩ; (generally can reach a cable length of 0~6 kilometers, mainly determined by the ground resistance and cable resistance)
LED Night Lighting The receiver has an LED flashlight function
LCD 3.5-inch color LCD
Dimensions Approximately 290mm (length)*128mm (width)*700mm (height)
Weight Approximately 1.90kg

 

HV HIPOT GD-4134E Handheld Cable Depth Path Detector for Underground Metal Pipeline

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now