HVHIPOT CT/PT Test Ratio Error & Angular Difference Tester with High Precusion

Product Details
Customization: Available
Input voltage: AC220V±10%, 50Hz
Working environment: -10ºC~50ºC, Humidity: ≤90%
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT CT/PT Test Ratio Error & Angular Difference Tester with High Precusion
  • HVHIPOT CT/PT Test Ratio Error & Angular Difference Tester with High Precusion
  • HVHIPOT CT/PT Test Ratio Error & Angular Difference Tester with High Precusion
  • HVHIPOT CT/PT Test Ratio Error & Angular Difference Tester with High Precusion
Find Similar Products

Basic Info.

Model NO.
GDHG-201P
CT Turns Ratio Test
1~40000, precision ±0.05%
PT Turns Ratio Test
1~40000, precision ±0.1%
Transport Package
Wooden Case
Specification
SGS, ISO
Trademark
HVHIPOT
Origin
China
HS Code
9030849000
Production Capacity
500set/Year

Product Description

General introduction

GDHG-201P CT/PT Analyzer is designed for analyzing current transformers and voltage transformers of protection or measurement use, adopts high-performance DSP and FPGA, advanced manufacturing process to ensure stable and reliable product performance, complete functions, high degree of automation, high test efficiency, which is suitable for laboratory and on-site test.


Features
  • Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT.
  • Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of transformers.
  • Accurately measure the ratio error and angular difference, the maximum allowable error of the ratio error is ±0.05%, and the maximum allowable error of the angular difference is ±2min. It can measure the 0.2S level current transformer, and the ratio measurement range is 1~40000.
  • Based on the advanced frequency conversion method to test CT/PT voltage-current characteristic curve and 10% error curve, the maximum AC voltage of 180V and AC current of 12Arms (36Apeak) can be output, but it can deal with the CT test of knee point up to 60KV.
  • Auto test CT/PT parameters such as knee point voltage/current, 5% and 10% error curve, accuracy limit factor (ALF), safety factor (FS), secondary time constants (Ts), magnetic remanence coefficient (Kr), saturated and unsaturated inductance.
  • The test meets various types of transformer standards such as GB1208 (IEC60044-1), GB16847 (IEC60044-6), and GB1207, and tests standards are automatically selected according to the type and level of the transformer.
  • The test is simple and convenient. CT DC resistance, excitation, ratio and polarity can be completed by one key. Besides burden test, all other tests of CT adopt the same wiring mode.
  • 5.7-inch graphic transflective LCD, clearly visible in the sun.
  • Operated with a rotating optical mouse, the operation is simple, fast and convenient, and easy to master.
  • Built-in printer, automatically prints the generated test report.
  • The test results can be exported by U disk, and the program can be upgraded with U disk, which is convenient and quick.
  • Save 1000 groups data and it is not lost after power down.
  • It is equipped with background analysis software to facilitate the storage, conversion and analysis of test reports, and can be used for comparison, judgment and evaluation of test data.
  • Easy to carry, device weight <10 kg.


Specification

Main parameters
Model GDHG-201P
Application CT, PT
Output 0~180Vrms, 12Arms,36A(Peak Value)
Voltage Measuring Precision ±0.1%
CT Turns Ratio Test Range 1~40000
Precision ±0.05%
PT Turns Ratio Test Range 1~40000
Precision ±0.1%
Phase Test Range ±2 min
Precision 0.5 min
Secondary winding resistance Test Range 0~300Ω
Precision 0.2%±2mΩ
AC burden Test Range 0~1000VA
Precision 0.2%±0.02VA
Input voltage AC220V±10%, 50Hz
Working environment Temperature:-10ºC~50ºC, Humidity: ≤90%
Dimension & Weight 365*290*153mm,10kg

HVHIPOT CT/PT Test Ratio Error &amp; Angular Difference Tester with High Precusion
HVHIPOT CT/PT Test Ratio Error &amp; Angular Difference Tester with High Precusion

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier