HVHIPOT Portable Six Phase Secondary Injector GDJB-1200A

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT Portable Six Phase Secondary Injector GDJB-1200A
  • HVHIPOT Portable Six Phase Secondary Injector GDJB-1200A
  • HVHIPOT Portable Six Phase Secondary Injector GDJB-1200A
  • HVHIPOT Portable Six Phase Secondary Injector GDJB-1200A
  • HVHIPOT Portable Six Phase Secondary Injector GDJB-1200A
  • HVHIPOT Portable Six Phase Secondary Injector GDJB-1200A
Find Similar Products

Basic Info.

Model NO.
GDJB-1200A
Transport Package
Standard Export Plywood Case
Specification
ISO9001
Trademark
HV HIPOT
Origin
Wuhan, China

Product Description

Portable Six Phase Relay Protection Tester System GDJB-1200A
 

General Description

GDJB-1200A Six Phase Relay Protection Test Set plays a key role in operating electricity power systems reliably and safely. It is the testing device used in the professional field of microcomputer protection, relay protection, excitation measurement, fault recorder.


Features
 

Flexible combination of voltage and current output
Six-phase voltage and six-phase current can be output, which has made it possible to be any combination, such as the output mode of the combination of conventional four-phase current and three-phase current, six phase voltage mode, six phase current mode and 12-phase output mode. It not only can be compatible with the traditional way of various tests but also can conveniently carry out differential tests of a three-phase transformer.
 
Operation mode
The device is directly connected to a computer or a desktop computer, which is convenient and efficient and stable performance.
 
A new hi-fi linear power amplifier
The output port has always insisted on using the modular linear power amplifier instead of the switching power amplifier, which has a high fidelity and high-reliability function and excellent performance. High-mid frequency will not be produced to disturb the test, also ensure the smoothing accuracy of the waveform produced by the whole course of the high current to the tiny current is excellent.
 
  1. High-performance Mainframe
The output part adopts DSP control, which has fast operation, real-time digital signal processing capability, wide bandwidth and high-resolution D/A conversion control. The output waveform has the features of high precision, small distortion and good linearity. With using a large number of advanced technology and precision components and materials and the structure of professional design, the device has the features of small volume, light weight, full function, easy to carry, boot can work, flow test is very convenient.

 
  1. Powerful software function
It can complete all kinds of high automatic validation work which is large and complex. It can also conveniently test and scan protection setting, playback of fault, real-time store test data, display vector, online print report and so on. Besides, six-phase current can facilitate the test of three-phase differential protection.

 
  1.  Independent DC power output
A 110V and 220V adjustable DC power is designed to supply output.
 
  1. Complete interface
The device with a USB communication port can communicate with the computer and other external devices
 
  1. Perfect self-protection function
With a reasonable design of the heat dissipation structure and reliable and perfect hardware protection measures, it has the power soft start function and the software of the fault self-diagnosis and the output latch function.


Technical parameters
 
AC Current Output
 
6-phase (RMS) 6*0~30A 
Accuracy 0.2%
3-phase (RMS) 3*0~60A
6-phase parallel current output (RMS) 0~180A
Allowable long-time working value of phase current (RMS) 10A
Maximum output power of phase current 450VA
Maximum output power when six phases parallel current output 1000VA
Allowable working hours @ max. the output of 6-phase parallel current 10s
Frequency range(fundamental wave)  0~1000Hz
Harmonic times 0~20 times
DC Current Output
 
Current output 0~±10A/phase;  output precision:   0.2 grade
Accuracy 0.2%
Maximum output load voltage 20V
AC Voltage Output
 
Phase voltage output (RMS) 0~120V   
Accuracy 0.1%
Line voltage output (RMS) 0~240V
Phase voltage/Line voltage output power 80VA/100VA
Frequency range (Fundamental wave) 0~1000Hz
Harmonic times 0~20 times
DC Voltage Output
 
Phase voltage output amplitude 0~±160V
Accuracy 0.2%
Line voltage output amplitude 0~±320V
Phase voltage/Line voltage output power 70VA/140VA
Binary
 
Binary input 8 channels input
Idle contact 1~20mA, 24V
Potential contact access "0": 0 ~+6V; "1": +11 V ~+250 V
4 channels output  DC: 220 V/0.2 A; AC: 220 V/0.5 A
Time Measuring Range  0.1ms~9999s        Measuring accuracy: <0.1mS