HVHIPOT 20kA Impulse Current Test System (GDCL-20)

HV Hipot Electric Co., Ltd.
  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Images of HVHIPOT 20kA Impulse Current Test System (GDCL-20)

HVHIPOT 20kA Impulse Current Test System (GDCL-20)
HVHIPOT 20kA Impulse Current Test System (GDCL-20) pictures & photos
HVHIPOT 20kA Impulse Current Test System (GDCL-20)
HVHIPOT 20kA Impulse Current Test System (GDCL-20) pictures & photos
HVHIPOT 20kA Impulse Current Test System (GDCL-20)
HVHIPOT 20kA Impulse Current Test System (GDCL-20) pictures & photos
HVHIPOT 20kA Impulse Current Test System (GDCL-20)
  • HVHIPOT 20kA Impulse Current Test System (GDCL-20)
  • HVHIPOT 20kA Impulse Current Test System (GDCL-20)
    HVHIPOT 20kA Impulse Current Test System (GDCL-20)
  • HVHIPOT 20kA Impulse Current Test System (GDCL-20)
    HVHIPOT 20kA Impulse Current Test System (GDCL-20)
  • HVHIPOT 20kA Impulse Current Test System (GDCL-20)
    HVHIPOT 20kA Impulse Current Test System (GDCL-20)

Find Similar Products

Product Description

HVHIPOT 20kA Impulse Current Test System (GDCL-20)
Applied standard
IEC 61643-21 AMD 1-2008 Part 21 of <Low Voltage Surge Protection Device> : Surge Protection Device from transmission network of telecommunication signals- Performance requirement and Test Method.
GB311.1-1997 Insulation coordination of HV Power transmission and transformation
GB/T16927.1-1997 High Voltage Testing Technique- General Testing Requirement
GB/T16927.2-1997 High Voltage Testing Technique- Measurement System
GB/T16896.1-1997 Digital Recorder of High Voltage Impulse Test
ZB F24 001-90 Implementation rules of Impulse Voltage Measurement 
GB191 Packing transportation mark
GB11032-2000 AC Gapless Metal Oxide Surge Arrester
JB/T563 Order Condition of Coupling Capacitor and Capacitive Voltage Divider 
GB4208 Protection class of Enclosure
GB18802.1-2002 SPD of Low Voltage Distribution System Part 1: Performance requirement and Test Method 
YD/T1235.1-2002 Technical Requirement of SPD used for Communication Station Low Voltage Distribution System 
YD/T1235.2-2002 Test Method of SPD used for Communication Station Low Voltage Distribution System 
YD/T 1542-2006 Technical Requirement and Test Method of Signal network SPD
QX10.1-2002 SPD Part 1: Performance requirement and Test Method 
Impulse Test Requirement: Meet GB18802.1 and YD/T1235.1 requirement.


Main technical data
GDCL-120kA Impulse Generator and Discharge unit
Max. Charge voltage ±100kV
Max. Capacity 10kJ
The quantity of Capacitor 1 pcs iron case Impulse Capacitor (lightning impulse current)
Capacitance 2μF/80kV/7pcs 10kJ
Output current waveform 8/20μs Standard Lightning Impulse Current Waveform 20kA

Specifications
Discharge Sphere Gap: Φ80 Pneumatic Sphere Gap.
Ignition mode of Discharge Sphere Gap: Pneumatic ignition
Basic circuit: linear and star-shaped arrangement

Shunt
Model number GF-1/120 Tube type
Rated impulse current 25kA
Resistance 4mΩ

Residual Voltage Divide
Model number RCF-10
Rated voltage 10kV
Voltage Ratio 10kV/100V

DC Charging Power Supply
Model Number DY50kV/62.5mA DY15kV/1000mA
Rated output voltage ±100kV, ±15kV
Rated output current 62.5mA, 1000mA
Polarity conversion Manual switch
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time, one month, Off Season Lead Time, one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified Production Machines
Assembling Line, Testing Line
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now