Customization: | Available |
---|---|
Mass Scope of Workpiece: | <900kg |
Type: | Universal Testing Machine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GDDO-20T Calibrator for AC Sampling and Transmitters takes DSP technology and 16 digit high speed A/D converter as core technology in AC sampler.
It has the features of high precision, good reliability, convenient to use.
Reference standard
Features
AC voltage range |
50V, 100V, 200V, 400V, 600V; Max. output capacity: 20VA |
AC current range |
0.5A, 1A, 2.5A, 5A, 10A, 20A; Max. output capacity: 20VA |
Adjustment range of AC voltage and current |
0~130% FS, fineness adjustment: 5×10-5 |
Accuracy of power frequency AC voltage and current |
0.05% FS |
Active power |
50~400V, accuracy: 0.05%FS |
Reactive power |
50~400V, accuracy: 0.1%FS |
Phase accuracy of current to same phase voltage |
0.050 |
Frequency
|
adjustment range: 45~65Hz, fineness adjustment: 0.001Hz, accuracy of setting value: 0.01Hz |
Phase |
adjustment range: 0~359.99°, fineness adjustment 0.01° |
Power factor |
adjustment range: 0~±1, fineness adjustment: 0.0001, accuracy of setting value: 0.0005 |
Waveform distortion of AC voltage and current output |
≤0.3% |
Stability of AC voltage, current and power output |
≤0.01% FS /60s |
Harmonic |
2nd~31th, amplitude: 0~40%, phase fineness of each harmonic: 0.010·N(N refers to harmonic order) |
DC voltage range |
75mV, 75V, 150V, 300V, 500V, 1000V, Max. output capacity: 20W |
DC current range |
0.5A, 1A, 2.5A, 5A, 10A, 20A, Max. output capacity: 20W |
Adjustment range of DC voltage and DC current |
0~120%FS (For 1000V: 0~105% FS), fineness adjustment: 5×10-5 |
Accuracy of DC voltage and DC current output |
≤0.01% FS /60s (Peak-peak) |
Setting value accuracy of DC voltage |
0.05%FS |
Setting value accuracy of DC current |
0.1%FS |
Accuracy of DC output (at 75mV, load ≥5Ω) |
0.1%FS |
DC measurement accuracy(for transmitter output and measurement) |
0.02%FS (Voltage: 0~±24V, current: 0~±24mA) |
Comprehensive error of electricity meter measurement (50~400V) |
0.05%(Pulse output: three phase rated value=6Hz) |
Power supply |
single phase 220V±10%, 50Hz±5% |
Use conditions |
20ºC±10ºC, ≤85%RH |
Size |
460*460*175mm |
Weight |
20kg (Upgraded version 24kg) |