This product is no longer promoted on Made-in-China.com. If you find any infringement or sensitive information of it, please contact us for handling. Thank you.

SF6 Gas Analyzer, purity, water content, decomposition products

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDSF-411WPD
Weight
5kg
Transport Package
Export Wooden Box
Specification
395*295*155mm
Trademark
HV Hipot
Origin
China
HS Code
9025800000
Production Capacity
5000sets/Year

Product Description

Factory Price Customized SF6 Gas Analyzer 

GDSF-411WPD is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP® series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer.

 

Application

 

Analysis of trace moisture, purity and decomposition products of SF6 gas electrical equipment for electric power
SF6 gas cylinder gas quality test
Quality test of SF6 gas for recovery and reuse
High purity gas manufacturing
Semiconductor industry dry gas supply
Research and development use
Clean room/dry house monitoring
Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases.

 

Features
  1. With self-calibration function, ensure the stability and reliability of moisture, purity and decomposition detection data throughout the year.
  2. All gas path with high polymer material design, ensures no water wall hanging phenomenon and guarantees the test speed.
  3. The oil-free stainless-steel body regulating valve is used to ensure the accuracy of the measured value.
  4. Advanced software algorithms improve the test accuracy of sensors.
  5. Combined chassis configuration solution, users can easily combine related instruments and accessories. The overall package is carried, which makes the user have a more relaxed experience.
  6. Start-up test, no need to preheat and oscillate.
  7. Temperature conversion and pressure data correction.
  8. Fuzzy computing technology.
  9. High-power lithium battery power, realize AC and DC dual power supply. No on-site AC power is required. Lithium battery power supply continues to work for more than 8 hours without the need of an external power supply.
  10. Anti-electromagnetic interference circuit design to ensure product reliability.
  11. Large-capacity memory, which can realize 1000 sets of data storage functions.
  12. The test data is stable and can provide both standard dew point values and converted dew point values at 20ºC.
  13. Purity measurement accuracy is 0.5% in the full range. It can be applied to the measurement of high concentration SF6 gas and 70% content SF6 gas.
  14. The best test flow area shows that the user can adjust the gas flow intuitively and quickly. Reduce test time.
  15. The air inlet is designed with a miniature self-sealing joint, and the air path to be tested will not leak when the air path is disconnected.
  16. With USB port, which can transfer data to PC.
  17. With gas recycling function, to recycle SF6 gas.


Specifications

SF6 Humidity

  1. Measurement method: Resistive and Capacitive measurement principle
  2. Measurement range: dew point -80ºC--+20ºC (support ppmv)
  3. Accuracy: ±1ºC
(when the dew point temperature is below 0 ºC, the sensor output is the frost point)
  1. Response time: 63% [90%]
+20→-20ºC Td 5s[45s]
-20→-60ºC Td 10s[240s]
  1. Resolution: 0.01ºC
  2. Repeatability:    ± 0.5 ºC
  3. Display unit: ºC, ppm, ºCP20(converted value at 20ºC)
  4. Gas flow: 400-600ml/min
  5. Flow display: 0-1000mL digital flow meter
  6. Sample gas pressure: ≤1MPa

SF6 Purity

  1. Measurement method: Infrared Measurement Principle (NDIR series sensors)
  2. Measuring range: 0 ~ 100% SF6
  3. Response time: [90%] 60s
  4. Accuracy: ± 0.5%FS
  5. Repeatability: ± 0.5%
  6. Resolution: 0.01%
  7. Display unit: %

SF6 Decomposition Products

  1. Measurement method: Electrochemical Measurements Principle (Electrochemical series sensors)
  2. Measurement range: H2S: 0 ~ 200ppmv
SO2: 0 ~ 200ppmv
  1. Accuracy: H2S: <10ppmv ±0.3ppmv; >10ppmv ±3%
SO2: <10ppmv ±0.3PPmv; >10ppmv ±3%
  1. Repeatability: H2S: <10ppmv ±0.2ppmv; >10ppmv ±2%
SO2: <10ppmv ±0.2PPmv; >10ppmv ±2%
  1. Resolution: 0.01ppmv
  2. Display unit: ppmv
  3. Recycling and filling function: recycling chamber 2L,
recycling time ≤ 5min
With gas drying function
  1. Power supply: 220VAC±10%, 50Hz, AC/DC use, over-charge protection, continuous working is no lower than 8hours.
  2. Use environment temperature: -20--+60ºC
  3. Environment humidity: 90%RH
  4. Measurement value influence: No effect of pressure and flow