• HVHIPOT GDAG-610 Insulation Gloves, Boots, Rod tester
  • HVHIPOT GDAG-610 Insulation Gloves, Boots, Rod tester
  • HVHIPOT GDAG-610 Insulation Gloves, Boots, Rod tester
  • HVHIPOT GDAG-610 Insulation Gloves, Boots, Rod tester

HVHIPOT GDAG-610 Insulation Gloves, Boots, Rod tester

After-sales Service: YES
Warranty: 1
Rated capacity: 10kVA
Input voltage: AC220V±10%, 50Hz±1
Output voltage: 0-50kV
Voltage accuracy: ≤ 2.0%(F.S)
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDAG-610
LV current
0-50A
Leak current
0-30.0mA
Resolution of leak current
0.1mA
Current accuracy
≤1.5%
Timing range
0-99h
Environmental temperature
-20ºC-50ºC
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
9030332000
Production Capacity
5000 Pieces/Year

Product Description

HVHIPOT GDAG-610 Insulation Gloves, Boots, Rod tester

Product Description

It is used to test insulation performance for insulation gloves, boots, rod, Electroscope etc.
It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods


Features

Manual control unit

  • Digital and real time display HV voltage, LV current.
  • With movable control unit, easy wiring and testing.
  • Manual control, safety and reliability.
  • With zero, power, operation, timing indicators.
  • With over-current protection, zero-start protection, sound and light alarm, power protected switch.
  • New type timer, broader timing range.(1s-99h)


Other features

  • HV source is oil immersed type testing transformer.(dry type and SF6 gas type for option.)
  • It is suitable for testing insulation gloves(boots), 6-10kV insulation rod.
  • To make test for insulation gloves and boots, the HV electrode is chain type, which the height can be adjusted. The material is stainless steel with CU/EpNi5bc painted, which make surface discharge<10pc. 6pcs insulation barrels are also supplied.
  • The electrode of insulation boots is red cooper voltage-sharing type, the HV inside the bottom of boots are equal distribution. 4mm steel balls supplied, not using traditional way that injecting water.
  • With insulation rod stand to make withstand voltage and leak test for insulation rod.
  • Control unit and HV unit are separate, to ensure safety.
  • If there is breakdown or over limits, the HV output will be cut off automatically and alarm.
Specifications
 
Rated capacity 10kVA
Input voltage AC220V±10%, 50Hz±1
Output voltage 0-50kV
Voltage accuracy ≤ 2.0%(F.S)
LV current 0-50A
Leak current 0-30.0mA
Resolution of leak current 0.1mA
Current accuracy ≤1.5%
Timing range 0-99h
Environmental temperature -20ºC-50ºC


Other Specifications for electroscope, insulation rod, mat test etc.

Insulation Rod
Voltage (kV) Interval distance of electrode mm Test voltage
(kV)
Test length
(m)
Time (min) Testing stand
10 400 45 0.7 1 GDJ-50
35 600 95 0.9 1 GDJ-50,
GDJ-100
63 700 175 1.0 1 GDJ-100,
GDJ-200
110 1000 220 1.3 1 GDJ-200,
GDJ-300
220 1800 440 2.1 1 GDJ-300 (section)
330 2800 380 3.2 5 GDJ-200 (section)
500 3700 580 4.1 5 GDJ-300 (section)

Send your message to this supplier