Partial Discharge (PD) Diagnostic System for Medium Voltage Cables

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • Oscillating Wave Test Method: Uses OWTS for on-site PD diagnostics of MV cables with frequencies from 50Hz to hundreds of Hertz.
  • High Voltage Output Capability: Delivers max DAC output voltage of 28kVpeak/20kVrms for effective testing.
  • Wide PD Measurement Range: Capable of measuring partial discharge from 1pC to 100nC accurately.
  • Advanced Digital Signal Processing: Features HV crystal switches, digital signal processors, and filters for precise diagnostics.
  • Cloud Computing Integration: Utilizes latest cloud technology to quickly solve various testing problems.
  • IEC 60270 Compliance: Operates in strict reference to the international IEC60270 standard.
  • Broad Frequency Range: Supports DAC frequency range from 50Hz to 800Hz for versatile applications.
  • Customization Services: ODM service available for tailored product solutions.

Product Images of Partial Discharge (PD) Diagnostic System for Medium Voltage Cables

Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables pictures & photos
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables pictures & photos
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables pictures & photos
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables pictures & photos
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables pictures & photos
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables pictures & photos
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
  • Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
  • Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
    Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
  • Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
    Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
  • Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
    Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
  • Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
    Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
  • Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
    Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
  • Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
    Partial Discharge (PD) Diagnostic System for Medium Voltage Cables

Find Similar Products

Product Description

Patial Discharge Test System with Oscillating Wave Method

General Information
GDOWS-10 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of MV Cables is an integrated partial discharge location and management system. Test frequency varies from 50Hz to hundreds of Hertz under damping AC voltage.
Damping AC voltage in the test can reach 28kV, combined with advanced hardware and software for diagnostics, mainly including:
  1. Latest transistor and laser control technology, such as HV crystal switch;
  2. Electronic components, digital signal processing, such as HV crystal switch and HV source;
  3. Digital signal processor and filter;
  4. Wireless and wired connection, built-in computer system includes PD detector, control unit and PD analyzer;
  5. Latest cloud computing technology, various problems can be quickly solved.

Specification
 
Max. DAC output voltage 28kVpeak/20kVrms
DAC frequency range 50~800Hz
Capacitance of cable 0.025~3uF
HV charging current 10mA
PD measurement range 1pC~100nC
Reference standard IEC60270
Bandwidth of PD location 150kHz~45MHz
Dielectric loss factor Tan δ 0.1%~10%
Power supply 110~240VAC,50~60Hz
Working temperature -10ºC~+40ºC
Weight 65kg

Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables
Partial Discharge (PD) Diagnostic System for Medium Voltage Cables


 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the maximum output voltage?
The system provides a maximum DAC output voltage of 28kVpeak/20kVrms.
What is the frequency range of the test?
The test frequency ranges from 50Hz to 800Hz.
What is the partial discharge measurement range?
The PD measurement range is from 1pC to 100nC.
Does the system support cable capacitance up to 3uF?
Yes, the system supports cable capacitance from 0.025uF to 3uF.
Is ODM service available for this product?
Yes, ODM service is available for customized solutions.
What is the average lead time for delivery?
The average lead time is one month for both peak and off-peak seasons.
What standards does the system comply with?
The system complies with the IEC60270 reference standard.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now