• HVHIPOT GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer
  • HVHIPOT GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer
  • HVHIPOT GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer

HVHIPOT GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer

After-sales Service: YES
Warranty: 1
Type: Universal Testing Machine
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Dynamic Load
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDE6500
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Size
263*168*65mm
Adapter input
110V-240V, 50Hz
Adapter output
15V, 3A
Transport Package
Standard Export Wooden Box
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
Production Capacity
5000set/Year

Product Description

HVHIPOT GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer
HVHIPOT GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer
HVHIPOT GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer
HVHIPOT GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer
GDE6500 Handheld Multi-functional Power Quality Harmonics Analyzer


General Information

GDE6500 Power quality analyzer is used for power quality analysis of power plants, transmission lines, distribution facilities, as well as general electricity, industrial electricity, railway and railways. It can measure voltage and current, harmonic, inter-harmonic, harmonic subgroup, high order harmonic, fluctuation, flicker, power and power factor, active power, reactive power, apparent power and rapid investigate surge current, voltage swell and sag, abnormal frequency, three-phase imbalance, transient over-voltage, short interruption and other abnormal phenomena.

Standard compliance
  1. Accuracy fully meets the standard IEC61000-4-30 class A.
  2. Harmonic measurement method fully meets the standard IEC61000-4-7.
  3. Flicker measurement principle fully meets the standard IEC61000-4-15.

Features
  1. Designed in strict accordance with the standards of the power industry, certified by state grid power laboratory center.
  2. Interface isolation design, more safe.
  3. Simple wiring, wide application. It can be applied to power quality analysis of any lines.
  4. High resolution 5.6-inch display with clear waveform.
  5. Equipped with protective wrist strap, labor-saving, safe and easy to operate.
  6. The transmission speed of USB can reach 4M/s, which is 2~4 times that of ordinary USB.
  7. Built-in 8G memory card, screen-shot picture can be stored up to 6500pcs.
  8. The damage rate is less than 1% during the free fall test at a height of 1.5 meters.
  9. Three-color waveform, easy to distinguish, intuitive.
  10. Built-in 8 kinds of wiring, applicable in various on-site conditions.
  11. With ruler function and zoom function, easy to see details.
  12. Automatic recording of measurement data.
  13. Automatic comparative analysis of historical data.
  14. The measurement accuracy reaches "0.1%", which is the highest in the industry.
  15. Screenshot function, support any interface screenshot, can be exported through USB connection.
  16. Support Chinese and English dual language, can freely switch
  17. The color of vector diagram can be used to judge whether the wiring is correct.
  18. Powerful report function. Reports in international standards is user-defined.
  19. Recording function: support 1-10mins Recording.
  20. Parameter settings can be saved. Support the call of different parameter settings.
  21. Support recorder mode. It can record all kinds of power parameters.
  22. With current transformers that supports general BNC interface (optional).


Specification
Mechanical Environment
Size 263*168*65mm Working condition 0ºC~+45ºC, <90%RH
Weight 2.0kg Storage condition -20ºC~+50ºC, <95%RH (no condensing)
Power supply Storage
Adapter input 110V-240V, 50Hz Type TF card
Adapter output 15V, 3A Capacity 8G
Battery Rechargeable lithium-ion battery 5000mAh Standard
Working time ≥5h Method IEC 61000-4-30
Charging time Min. 5 hours (ambient temperature 25ºC) Performance IEC 61000-4-30 class A
Power saving function LCD backlight brightness and standby time are adjustable. Flicker IEC 61000-4-15
Display Harmonics IEC 61000-4-7
Size 112.8*84.6mm Power decomposition IEEE 1459
Color 260K color Crosstalk
Resolution 640*480 Between voltage input terminals -60dB (at nominal frequency)
Brightness Max. 350 cd/m²(Typ.), brightness adjustable Between voltage and current input terminals -95dB (at nominal frequency)
Contrast 500:1 (Typ.) Common-mode suppression
Viewing angle 70/70/50/70 (Typ.)(CR≥10)  (Left/Right/Up/Down) CMRR >60dB
Electromagnetic compatibility Environment reliability
Standard Class 4: GB/T 17626.2-2006 Electrostatic Discharge Immunity Test Standard GB/T 2423.1-2008: low temperature
Class 3: GB/T 17626.3-2006 Radiated, Radio Frequency Electromagnetic Field Immunity Test GB/T 2423.2-2008: high temperature
Class 3: GB/T 17626.4-2008 Electrical Fast Transient/burst Immunity Test GB/T 2423.4-2008 High and low temperature alternating humidity heat test
Class 3: GB/T 17626.5-2008 Surge Immunity Test GB/T 2423.5-1995 Shock
Class 3: GB/T 17626.8-2006 Power Frequency Magnetic Field Immunity Test GB/T 2423.10-2008 Vibration
Class 3: GB/T 17626.9-1998 Pulse Magnetic Field Immunity Test GB/T 2423.22-2002 Temperature change
Class 3: GB/T 17626.12-1998 Oscillatory Waves Immunity Test  
Safety
Standard compliance GB 4793.1-2007/IEC 61010-1:2001: Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Part 1: General Requirements
Safety class: CATIII 1000V/CATIV 600V
Banana input terminal CATIII 1000V/CATIV 600V
 
Function Item Content
Recorder Oscilloscope Real-time voltage waveform of A, B, C and N phase
Voltage


Current


Frequency
  1. Voltage effective value, effective value of voltage half-wave, voltage positive peak, voltage negative peak, voltage waveform factor
  2. Current effective value, effective value of current half-wave, current positive peak, current negative peak, current waveform factor
  3. Frequency
Power and electric energy Active power, reactive power, apparent power, power factor, displacement power factor, active energy, reactive energy, apparent energy.
Voltage harmonic THD, DC, 1st~50th harmonic, 0~49th inter-harmonic, 1st~35th high order harmonic.
Current harmonic THD, DC, KF, 1st~50th harmonic, 0~49th inter-harmonic, 1st~35th high order harmonic.
Harmonic power THD, DC, 1st~50th harmonic power.
Flicker PST (short-term flicker), PLT (long-term flicker) .
Imbalance Positive sequence voltage, positive sequence current, negative sequence voltage, negative sequence current, zero sequence voltage, zero sequence current, imbalance.
Energy consumption Power decomposition of active power, reactive power, apparent power, power of line loss, cost of line loss, pollution evaluation.
Demand Demand
Event recording Voltage swell, voltage sag, voltage interruption, surge current, over limit of PST, over limit of PLT, over upper limit of voltage, over lower limit of voltage, over upper limit of frequency, over lower limit of frequency, fluctuation of steady state voltage, over limit of voltage imbalance, over limit of voltage THD, over limit of 1st~50th voltage harmonic, over limit of 2nd~50th current harmonic.
Inverter DC DC voltage, DC current, DC power, ripple voltage, content ratio of ripple voltage.
AC Frequency, voltage effective value, current effective value, total apparent power, total active power, total power factor, fundamental power, fundamental power factor.
Efficiency Conversion efficiency
Transient Voltage Voltage effective value, effective value of voltage half-wave, voltage positive peak, voltage negative peak.
Current Current effective value, effective value of current half-wave, current positive peak, current negative peak.
Frequency Frequency
Event recording Voltage swell, voltage sag, voltage interruption.
Monitor
Monitor
Voltage effective value, 1st~50th voltage harmonic, PLT, voltage swell, voltage sag, voltage interruption, fluctuation of steady state voltage,voltage imbalance
 
Parameter Type Content
Frequency Nominal frequency 50Hz/60Hz
Measurement method Calculation of 10/12 cycles.
Resolution 0.001Hz
Width range 42.5Hz~69Hz
Measurement accuracy ±0.001Hz
Voltage effective value Measurement method Calculation from mean square value of 10/12 cycles.
Resolution 0.001V
Measurement range 1V ~ 1000V
Measurement accuracy 0.1% of nominal voltage
Current effective value Measurement method Calculation from mean square value of 10/12 cycles.
Resolution 0.001A
Measurement range Different CT varies in measurement range.
Measurement accuracy 0.1%+CT accuracy
Power Measurement method P=(U1*I1)2 (of 10 wave cycles)
S=U2*I2 (of 10 wave cycles)



U1: instantaneous value of voltage
I1: instantaneous value of current
U2: effective value of voltage
I2: effective value of current
P: active power
Q: reactive power
S: apparent power;
Cos φ: power factor
 
Resolution 0.001W
Measurement range It depends on voltage range and range of CT.
Measurement accuracy 0.5%+CT accuracy
Voltage and current harmonic Measurement method Based on IEC61000-4-7, window amplitude analysis of 10 wave cycles
Test item Effective value, content ratio, phase angle
Number of times/frequency 50th /50Hz-2500Hz
Measurement accuracy
  1. Voltage harmonic > 1% nominal value: error <1%readings
  2. Voltage harmonic < 1% nominal value: error <0.05% nominal voltage
  3. Current harmonic > 3% nominal value: error < (1%readings+CT accuracy)
  4. Current harmonic < 3% nominal value: error < (0.05%F.S.+CT accuracy)
Inter-harmonic current and voltage Measurement method Based on IEC61000-4-7, window amplitude analysis of 10 wave cycles
Test item Effective value, content ratio, phase angle
Number of times/frequency 50th /25Hz~2475Hz
Measurement accuracy
  1. Voltage harmonic > 1% nominal value: error <1%readings
  2. Voltage harmonic < 1% nominal value: error <0.05% nominal voltage
  3. Current harmonic > 3% nominal value: error < (1%readings+CT accuracy)
  4. Current harmonic < 3% nominal value: error < (0.05%F.S.+CT accuracy)
Harmonic power Measurement method Based on IEC61000-4-7, window amplitude analysis of 10 wave cycles
Test item Effective value, content ratio, phase angle
Number of times/frequency 50th /50Hz~2500Hz
Measurement frequency
  1. Voltage harmonic > 1% nominal value: error < (1%readings+CT accuracy)
  2. Voltage harmonic < 1% nominal value: error < (0.05% nominal voltage+CT accuracy)
 
Parameter Type Content
High order harmonics of voltage and current Measurement method Based on IEC61000-4-7, window amplitude analysis of 10 wave cycles
Measurement type Effective value, content ratio, phase angle
Number of times/frequency 35th / 2100Hz~8900Hz



Measurement accuracy
  1. Voltage harmonic > 1% nominal value: error <1%readings
  2. Voltage harmonic < 1% nominal value: error <0.05% nominal voltage
  3. Current harmonic > 3% nominal value: error < (1%readings+CT accuracy)
  4. Current harmonic < 3% nominal value: error < (0.05%F.S.+CT accuracy)
Imbalance

Measurement method
  1. Imbalance of voltage negative sequence: the ratio of negative sequence voltage to positive sequence voltage
  2. Imbalance of voltage zero sequence: the ratio of zero sequence voltage to positive sequence voltage
  3. Imbalance of current negative sequence: the ratio of negative sequence current to positive sequence current
  4. Imbalance of current zero sequence: the ratio of zero sequence current to positive sequence current
Resolution 0.001%
Measurement accuracy Voltage imbalance: ±0.2%
Current imbalance: ±0.5%
Flicker Test item Short-term flicker (PST), long-term flicker (PLT)
Measurement method According to IEC61000-4-15, PST (10 minutes) and PLT (2 hours) are calculated.
Measurement range 0 ~ 20
Measurement accuracy ±5%

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now