Customization: | Available |
---|---|
Type: | Universal Testing Machine |
Accuracy Grade: | 0.1 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Accuracy level | 0.1 class |
Output voltage | 3*100V/57.7V Y 3*100V 3*380V/220V Y 3*380V Regulating range: 0-120% continuously adjustable Regulating fineness: better than 0.01% * Special voltage range can be set up according to user order. |
Current range | 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, 50A, 100A Regulating range: 0-120% consecutively adjustable Regulating fineness: better than 0.01% |
Output power | (voltage loop) 800VA (current loop) 1200VA |
Stability of output voltage, current and power | ≤0.05%/120S PF=1 (0.1 class type) |
Wave distortion of output voltage and current | ≤0.5% |
Symmetry of three phase | better than 120° +0.3° |
Frequency range | 45Hz~65Hz |
regulating accuracy | 0.1 Hz |
Phase shifting range | -180.0°-180.0° |
Regulating accuracy | 0.1° |
Standard crystal oscillator stability | ≤10-7/s |
Indicating instruments class | Voltmeter and ammeter accuracy: level±0.2% Phase meter accuracy: ±0.5° Frequency meter accuracy: ±0.01Hz |
Maximum meters for test | 20 |
Power supply | 3*220V±10%, 50Hz |
Maximum power consumption | 3200VA |
Working temperature | 20±5ºC |
relative humidity | ≤85% |
Dimensions | 2500mm * 750 mm * 2000 mm |
Weight | 400kg |