GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply can be obtained. There are four strong magnets on the back of the instrument, which can be attached to the distribution box for use.
GDCR1000C, GDCR1000D non-contact phase tester has the functions of looping inspection, simple power inspection, circuit breaking search, breakpoint location, line maintenance and so on.
Test wire outer diameter:
GDCR1000C: ø1.6mm~ø16mm
GDCR1000D: ø10mm~ø40mm
Function |
Phase check(positive phase, reverse phase, missing phase), live line check, break-point location , line maintenance |
Power supply |
DC 3 V 2 section alkaline dry cell (LR 6), continuous use time of about 70 hours |
Live range |
AC 70~1000 V, 45~65 Hz (sine wave continuous input) |
Test wire size |
Outer diameter ø1.6 mm~ø16 mm or ø10 mm~ø40 mm(optional) |
LED display |
[positive phase] 4 phase detection lights turn on clockwise in turn; [reverse phase] 4 phase detection lights turn on clockwise sequentially. [live line] L1, L2 and L3 lights turn on within the range of voltage setting; [missing phase] L1 or L2 or L3 lights are not on. [open circuit] The L1 or L2 or L3 lights are not on. |
Buzzing |
[positive phase] instrument emits intermittent short buzz; [reverse phase] The instrument emits continuous long sounds. |
Battery Indication |
POWER indicator lights up after power on; LOW BATTERY lights up when power is insufficient |
Magnetism |
There are four magnets attached to the back of the instrument, which are attached to the distribution box and can withstand 800 g quality. |
Shut off |
After about 5 minutes, the instrument shuts down automatically. |
Dimension |
L 70 mm* H 75 mm* W 30 mm |
Clamp wire length |
0.6 m |
Weight |
About 200 g (include battery) |
Working condition |
-10ºC~55ºC;<80%rh |
Storage condition |
-20ºC~60ºC;<90% r |
Measurement max. voltage |
AC 1000 V |
Dielectric strength |
5.4 kVrms |
Max. rated power |
300 mVA |
Standards |
EN 61010-1:2001, EN 61010-031:2002, pollution class 2, CAT III (600 V), transient over-voltage 6000 V |