Product Highlights

  • Integrated High Voltage Testing: Built-in bridge, variable frequency supply, and transformer for capacitance and dielectric loss testing.
  • Comprehensive CVT Analysis: Tests C1/C2 dielectric loss, capacitance, transformation ratio, and voltage angle difference simultaneously.
  • Multi-Mode Testing Flexibility: Supports internal/external high voltage, inner/external standard, and self-excitation modes.
  • Advanced Data Management: Stores 200 groups of results with calendar chip; exports data via USB flash disk.
  • LCR Automatic Measurement: Measures and displays inductance, capacitance, resistance, and angle with high precision.
  • Robust Safety Protections: Features multiple protections against voltage fluctuation, short circuit, over-voltage, and over-current.
  • Flexible Frequency Options: Supports 50Hz, 60Hz, and multiple dual frequencies (e.g., 45Hz/55Hz) for anti-interference.

Product Images of HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester

HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester pictures & photos
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester pictures & photos
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester pictures & photos
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester pictures & photos
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester pictures & photos
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester pictures & photos
HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
  • HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
  • HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
    HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
  • HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
    HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
  • HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
    HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
  • HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
    HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
  • HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
    HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
  • HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester
    HV HIPOT Transformer 10kV  12kV Tan Delta Tester Power Factor Tester

Find Similar Products

Product Description

GD6900 Capacitance and Dissipation Factor Tester

HV HIPOT Transformer 10kV 12kV Tan Delta Tester Power Factor Tester
Product Description

GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.

High voltage source is generated by internal inverter of the instrument, which is used for testing test object after transformer boost. If adding a insulation cup and temperature control device, dielectric loss of insulating oil can be tested.Features
 

  1. Touch LCD screen display.
  2. Insulation resistance test: Built-in insulation resistance test module, can carry out  Insulation resistance (IR), absorption ratio (DAR), polarization index (PI) test
  1. Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
  2. The instrument data can be exported through U disk.
  3. Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
  4. Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
  5. The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
  6. High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
  7. LCR automatic measurement. Inductance, capacitance, resistance, angle can be measured and displayed.
  8. Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
  9. No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
  10. Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
    Product Parameters

    Specifications

    Working condition -15ºC~40ºC RH<80%
    Anti-interference principle Frequency conversion
    Power supply AC 220V±10%, 50/60Hz Generator can be used.
    High voltage output AC 0.5KV~10KV (12kV optional) Every 0.1kV
    Accuracy 2%
    Max. current     200mA
    Capacity 2000VA
    Self-excitation power AC 0V~50V/15A 50Hz, 60Hz single frequency
    45HZ/55HZ  47.5HZ/52.5HZ
    55HZ/65HZ  57.5HZ/62.5HZ
    Automatic dual frequency
    Resolution tgδ: 0.001% Cx: 0.001pF
    Accuracy tgδ: ±(reading*1.0%+0.040%)
    C x: ±(reading*1.0%+1.00PF)
    Measurement range tgδ Without limit
    C x 15pF < Cx < 300nF
    10KV Cx < 60 nF
     5KV Cx < 150 nF
     1KV Cx < 300 nF
    CVT test Cx < 300 nF
    LCR measurement range L>20H(2kV) R>10KΩ(2kV)
    LCR measurement accuracy 0.1% Resolution 0.01
    CVT ratio range 10~10000
    CVT ratio accuracy 0.1%
    CVT ratio resolution 0.01
    Insulation resistance DC high voltage 5~10kV Accuracy ±(2%*Reading +10V)
    IR accuracy 100kΩ-1000GΩ: <5% (test voltage not less than 250V)
    100GΩ-1000GΩ: 10% (test voltage not less than 10000V)
     
    Dimension Main unit: 350(L)×270(W)×270(H)
    Accessory box: 350(L)×270(W)×160(H)
    Memory capacity 200 groups, USB flash disk storage is supported.
    Weight Main unit: 22.75Kg
    Accessory box: 5.25Kg
HV HIPOT Transformer 10kV 12kV Tan Delta Tester Power Factor TesterHV HIPOT Transformer 10kV 12kV Tan Delta Tester Power Factor TesterHV HIPOT Transformer 10kV 12kV Tan Delta Tester Power Factor TesterHV HIPOT Transformer 10kV 12kV Tan Delta Tester Power Factor Tester
Company Profile

HV HIPOT Transformer 10kV 12kV Tan Delta Tester Power Factor Tester

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the warranty period for this tester?
The product comes with a 1-year warranty.
What is the maximum high voltage output?
The standard output is AC 0.5KV~10KV, with an optional 12KV high voltage output.
Can this device test Capacitive Voltage Transformers (CVT)?
Yes, it can test CVT C1 and C2 dielectric loss and capacitance simultaneously, as well as transformation ratio and voltage angle difference.
How is the test data stored and exported?
It stores up to 200 groups of results internally and supports exporting data via a USB flash disk.
Does the device support LCR measurements?
Yes, it features LCR automatic measurement for inductance, capacitance, resistance, and angle.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now