Customization: | Available |
---|---|
Application: | Power, Electronic, Instrument |
Phase: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
A. Control unit specifications
Power |
AC220V±10%,50Hz |
Capacity |
5kVA |
Output voltage |
AC 0-250V |
Rated output current |
25A |
Rated current rectified range |
0-25A |
HV voltmeter range |
0-75kV Accuracy: 1.5% of the reading±1digit(F.S) |
HV ammeter range |
0-105mA Accuracy: 1.5% of the reading±1 digit(F.S) |
LV ammeter range |
0-30A Accuracy: 2.0% of the reading±1 digit(F.S) |
Timing range |
1s-99h |
Weight |
21kg |
Dimension |
440mm (L)*340mm (W)*240mm (H) |
B. Testing transformer (HV unit) specifications
LV side voltage (Input voltage) |
0-200V |
LV side current (Input current) |
AC 0-25A |
HV side voltage(Output voltage) |
AC 0-50kV, DC 0-70kV |
HV side current(Output current) |
AC 100mA, DC 71.4mA |
Capacity |
5kVA |
HV side/LV side turns ratio |
250:1 |
Measuring voltage |
AC 0-100V Accuracy: 1.5% of the reading±1 digit(F.S) |
No-load current |
<10% |
Impedance voltage |
<10% |
Weight |
35kg |
Dimension |