GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • Automatic PLC Control: Features 7-inch color LCD screen with PLC automation for precise and simple operation.
  • High Precision Measurement: Simultaneously measures HV voltage, LV current, LV voltage, and leakage current with high accuracy.
  • Customizable Rated Capacity: Rated capacity of 5kVA can be customized to meet specific application requirements.
  • Adjustable Electrode Gap: Electrode gap is arbitrarily adjustable between 400mm, 500mm, and 600mm.
  • Extensive Data Storage: Stores up to 8000 test data points within 3 months with USB port for data upload.
  • Comprehensive Safety Protection: Includes over-voltage, over-current, flash-over protection, and automatic zero-starting functions.
  • Flexible Operation Modes: Offers both automatic and manual modes for versatile testing scenarios.
  • Robust Anti-Interference Design: Features software and hardware anti-interference design for harsh electromagnetic environments.

Product Images of GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control

GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control pictures & photos
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control pictures & photos
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control pictures & photos
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control pictures & photos
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control pictures & photos
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control pictures & photos
GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
  • GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
  • GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
    GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
  • GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
    GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
  • GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
    GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
  • GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
    GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
  • GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
    GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
  • GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control
    GDJS-15A Insulation High Voltage Testing for Safety  Helmet 50kV with Automatic control

Find Similar Products

Product Description

Customized GDJS-15A Insulation High Voltage Test for Safety Helmet 50kV
GDJS-15A Insulation High Voltage Testing for Safety Helmet 50kV with Automatic control

 

 

I. General Information

 

GDJS-15A Safety Helmet Test Set is special equipment for insulated helmet. The test procedure is simple and personnel security is guaranteed. Parameters such as leakage current, high voltage and withstand voltage curve can be obtained reliably.

The equipment is composed of power frequency voltage withstanding test device, special test electrode for helmet and leakage HV ammeter. It has the advantages of simple wiring and detection, reasonable and reliable layout, convenient movement, flexible dis-assembly and assembly, etc.

 

 

II. Features

7inch color LCD screen, with PLC automation control.

HV Voltage, LV Current, LV voltage, LV current measured at the same time, with high precision sensor and high performance collection chip.

Automatic mode and manual mode for option.

Display HV voltage, LV voltage, LV current, time and withstand voltage result.

Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set.

Zero-starting function. Test can be proceed after the voltage is back to zero.

Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk.

When setting voltage is arrived, it will timing automatically. After timing, voltage will be back to zero.

When the LV current is over setting value, the voltage will be cut off automatically and it will be back to zero. After the flash-over protection value is exceeded, the automatic step-down zero protection is performed.

Software and hardware anti-interference design, a variety of anti-interference means, to adapt to harsh electromagnetic environment.

Automatic error diagnosis, easy to find and solve problems, simple equipment maintenance.

 

 

Other features

 

Arbitrary combination of high voltage power source, test electrode and leakage ammeter, wiring operation is convenient and flexible.

HV source is oil immersed type testing transformer.

Control unit and HV unit are separate, to ensure safety.

If there is breakdown or over limits, the HV output will be cut off automatically and alarm.

 

III. Technical Specifications

 

A. GDYD-55A Control Unit

 

Rated capacity: 5kVA

Input voltage: AC220V±10%, 60Hz±1

Output voltage: 0-50kVAC

Voltage accuracy: ≤2.5% (F.S)

Low voltage current: 0-25A

Leakage current: 0-30.0mA

Leakage current resolution: 0.1mA

Current accuracy: ≤2.0% (F.S)

Timing range: 0-99.9H

Environmental temperature: -20ºC to 50ºC

Environment humidity: ≤85% RH (no condensing)

 

B. Testing transformer (HV unit) specifications

 

Input voltage: 0-200V

Input current: AC 0-25A

Output voltage: AC 0-50kV

Output current: AC 100mA

Capacity: 5kVA

HV side/LV side turns ratio: 250:1

Measuring voltage: AC 0-100V

    Accuracy: 1.5% of the reading±1 digit (F.S)

No-load current: <10%

Impedance voltage: <10%

Weight: about 45kg

Dimension: 350mm(L)* 250mm(W)* 640mm(H)

 

C. GDM Helmet Electrode

 

Working mode: continuously working

Dimension: 830mm *570mm *1340mm

Weight: 67kg

Max. Withstand voltage: 50kV

Electrode gap: 400mm 500mm, 600mm can be adjustable arbitrarily.

 

D. Working conditions

 

Working place: No gas, steam, chemical dust and explosive and corrosive medium which will influence insulation.

Environment temperature: -20--50ºC

Environment humidity: ≤85% RH (no condensing)

GDJS-15A Insulation High Voltage Testing for Safety Helmet 50kV with Automatic controlGDJS-15A Insulation High Voltage Testing for Safety Helmet 50kV with Automatic control

GDJS-15A Insulation High Voltage Testing for Safety Helmet 50kV with Automatic controlGDJS-15A Insulation High Voltage Testing for Safety Helmet 50kV with Automatic controlGDJS-15A Insulation High Voltage Testing for Safety Helmet 50kV with Automatic controlGDJS-15A Insulation High Voltage Testing for Safety Helmet 50kV with Automatic control

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the warranty period for this equipment?
We provide a 1-year warranty for all mechanical defects.
Can the rated capacity and voltage be customized?
Yes, both the rated capacity (5kVA) and rated voltage (50kV) can be customized according to your needs.
What is the maximum withstand voltage?
The equipment supports a maximum withstand voltage of 50kV.
How is the electrode gap configured?
The electrode gap is adjustable and can be set arbitrarily to 400mm, 500mm, or 600mm.
Does the device support data storage and export?
Yes, it can store up to 8000 test data points and includes a USB port for uploading data to a disk.
Is there a lead time for orders?
The average lead time is one month, applicable for both peak and off-peak seasons.
What payment terms are accepted?
We accept LC and T/T as terms of payment.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now