AC hipot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus or machines. It checks dangerous flaws which assure electrical equipment continuous working.
Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators.
GDYD series AC Hipot Test Set is composed of control unit and AC testing transformer (HV unit) which output AC voltage smoothly. Meanwhile, it has many monitoring and protection functions.
Features
- Digital display meters mounted on the panel.
- Monitoring HV side voltage, HV side current, LV side current and indicator of zero, power, working start, timing.
- Over-current protection, zero-starting protection,sound and light alarm.
- With new type time relay, time rang is more wider (1S ~ 99H).
- Using the latest current relay, more accurate and reliable.
- Light weight, small size, easy to move.
Technical Specifications
Control unit specifications
- Power: AC 220V±10%, 50Hz or 60Hz
- Capacity: 10kVA
- Output: AC 0-200V
- Rated output current: 25A
- HV voltmeter range: 0-100kV
Accuracy: 3% of the reading±1digit(F.S)
6.HV ammeter range: 0-100mA
Accuracy: 3% of the reading±1 digit(F.S)
7. LV ammeter range: 0-25A
Accuracy: 2.0% of the reading±1 digit(F.S)
8. Timing range:1s-900s
9. Weight: about 55kg
10.Dimension: 535mm*575mm*1070mm
Testing transformer (HV unit) specifications
- LV side voltage: 0-200V
- LV side current: AC 0-50A
- HV side voltage: AC 0-100kV
- HV side current: AC 0-100mA
- Capacity: 10kVA
- HV side/LV side turns ratio: 500:1
- Measuring voltage: AC 0-250V
Accuracy: 1.5% of the reading ±1 digit(F.S)
8. No-load current: less than 4%
9. Impedance voltage: less than 12%
Working conditions
- Working place: No gas, steam, chemical dust and explosive and corrosive medium which will influence insulation.
- Environment temperature: -20--50ºC
- Environment humidity: ≤85% RH (no condensing)
![HVHIPOT GDYD-1010D Digital AC Hipot Test Set (10kVA,100kV)](//www.micstatic.com/athena/img/transparent.png)
![HVHIPOT GDYD-1010D Digital AC Hipot Test Set (10kVA,100kV)](//www.micstatic.com/athena/img/transparent.png)
![HVHIPOT GDYD-1010D Digital AC Hipot Test Set (10kVA,100kV)](//www.micstatic.com/athena/img/transparent.png)
![HVHIPOT GDYD-1010D Digital AC Hipot Test Set (10kVA,100kV)](//www.micstatic.com/athena/img/transparent.png)