• HV HIPOT GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution
  • HV HIPOT GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution
  • HV HIPOT GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution
  • HV HIPOT GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution
  • HV HIPOT GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution

HV HIPOT GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution

After-sales Service: Yes
Warranty: 1 year
Power supply: 220V, AC, 5kVA
Rated charging voltage: 20kV
Total capacitance: 9uFX1
Rated power: 18kJ
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
GDCL-V
wave-front time
8μS±10%
Virtual impedance
2ohm
Transport Package
Standard Wooden Package
Specification
ISO, SGS
Trademark
HV HIPOT
Origin
Wuhan China
Production Capacity
2000PCS/Year

Product Description

HV HIPOT GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution
Product Description

 

HV HIPOT GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution

General Information

It is mainly used for composite wave testing of level III SPD,to generate bigger lightning impulse and current.This model 20kV/10kA is designed according to IEC61000-4-5 and GB/T17626.5-1999, the stipulation of Voltage wave&combination waveform, and signal generator features and performance, coupling and decoupling network.Also it is designed accorded with IEC61643-11 and GB/T18802.1-2002, the stipulation of Level I and II SPD impulse voltage testing, and level III SPD composite wave testing.

Main Features and Specifications

1. Waveform requirement and output range

  • Short-circuit current Isc: wave-front time 8μS±10%, half peak time 20μS±10%, peak value ±10%
  • At wave crest, ≥5% peak value of Current overshoot or vibration is not permitted.If current wave has reversed polarity vibration, then ≤20% peak value. Short-circuit current peak value 1kA-10kA.
  • Virtual impedance: 2Ω

2. Pointer voltmeter and digital voltmeter display for charging voltage. Positive shock and negative shock can be realized.

3. With impulse current display, accuracy ±1%

4. Output voltage measurement

  • With impulse voltage divider(voltage ratio accuracy ±1%), output to BNC socket of panel, for oscillograph connection.

5. Protection device

  • The instrument has enough safety device, ensure safe operation.
    Product Parameters
    Power input 220VAC, 5kVA
    Rated charging voltage 20kV
    Total capacitance 9μF×1
    Rated capacity 18kJ