Type: | hipot test |
---|---|
Maxcapacity: | <1000KN |
Accuracy Grade: | 1 |
Load Way: | Electronic Load |
Loading Method: | Static Load |
Display: | Digital |
Customization: |
---|
Suppliers with verified business licenses
Items(kV/mA) parameter |
50/80 | 50/150 | 60/200 | 60/300 | 80/200 | 80/300 | ||
Output voltage(kV) | 50 | 50 | 60 | 60 | 80 | 80 | ||
Output current(mA) | 80 | 150 | 150 | 300 | 200 | 300 | ||
Output power(W) | 4000 | 7500 | 9000 | 18000 | 16000 | 24000 | ||
Voltage measurement error | ≤ 1.0% ± 1digit | |||||||
Current measurement error | ≤ 1.0% ± 1digit | |||||||
Overvoltage setting error | ≤ 1.0% | |||||||
Ripple coefficient | ≤ 3.0% | |||||||
Voltage stability | ≤ 1.0% | |||||||
Power supply | AC220V | AC380V(three phase, four wire) |