HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)
  • HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)
  • HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)
  • HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)
  • HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)
Find Similar Products

Basic Info.

Model NO.
GDCL-20kA
Maxcapacity
10ka
Accuracy Grade
1.5
Load Way
Electronic Load
Loading Method
Static Load
Display
Touch Screen Display
Control
PLC
Weight
100-500Kg
Power Source
AC Meter
Oil Cylinder Position
No
Installation
Portable Precise
Theory
Electric Apparatus
Application
Electronic Equipment, Electric Power
Test Object
Voltage dependent resistor, Gas discharge tube, SP
Charge voltage
0-100.0kV 0-15kV
Current  range
1kA-10kA, Max. 12kA
Capacitor capacity
2μF/80kV/7set 10kJ
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
HS Code
8543709990
Production Capacity
500PCS/Year

Product Description

HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)

Description

The fully automatic comprehensive test system of the impulse current device is mainly applied to the impulse current test of the lightning arrester device (lightning protection device). The use environment is indoors, the altitude is not more than 1500 meters, and the ambient temperature is -10 °C~40 °C. The relative humidity is not more than 90%.



GDCL-20kA impact generator body and discharge test rack platform. 

1.Model: GDCL-20kA
2.Maximum charging voltage: ±100kV, maximum energy storage: 10kJ.
3.Capacitors: 1 iron-shell pulse capacitor (lightning impulse current)
4. Capacitor Capacitance: 2μF/80kV/7 units 10kJ

5.discharge ball gap: Φ80 pneumatic ball gap.
6. discharge ball gap ignition mode: pneumatic ignition.
7.basic circuit arrangement: straight line and star arrangement
8.mpulse current shunt
9. model: GF-1/20 tubular impact shunt
10.rated inrush current: 25kA
11.resistance value: 4mΩ
12.residual voltage divider
13. Model: RCF-10
14.rated voltage: 10kV
15. partial pressure ratio: 10kV/100V
16.DC charging power supply
17. Model: DY50kV/62.5mA DY15kV/1000mA
18. rated output voltage: ±100kV ±15kV
19. rated output current: 62.5mA 1000mA
20. polarity conversion: manual switching


GDCL-2000A automatic control system technical parameters
1 charging voltage: setting range 0~100.0kV, 0~15kV
2 working range: 10.0~80.0kV, 1kV~15kV
3 Setting deviation: ≤±1%
4 instability: ≤ ± 1%
5 tuning resolution: 0.1kV
6 charging time: setting range 5~180s
7 impact test interval: setting range 1~999s
8 tuning resolution 1s
9 trigger control: manual or automatic, can be set
10 Impact test times: Setting range 1~999 or 1~99999
11 protection settings:
11-1 charging overcurrent protection value, can be set
11-2 overvoltage protection value, can be set
11-3 dynamic charging protection, optional
11-4 static charging protection, can be set
 
Impulse  waveform
Short  circuit  current  waveform 8/20ms Allowable  deviation
 
Wavefront  time 8ms ± 10%
Half  peak  time 20ms ± 10%
Current  range 1kA-10kA, Max. 12kA
Standard Waveform  is  smooth, accorded  with  IEC  standard.






Major  loop
Constant  voltage  charge Three  level  subsection,   charging  time  Max. 40secs
  Auto  ground Electromagnet
  Transformer AC  15kV/500VA   
      Rectification Half-wave  rectification 1pcs  high  voltage  silicon  stack
  Polarity  Positive  or  negative
  Charging  voltage  measurement Resistive  divider
 
Discharging  loop
capacitor 15kV/16uf    1piece
    capacity 1800J
    Wave-adjusting  resistor    1piece
    Wave-adjusting  inductance    1piece
    Discharge  ball Control  switch
Measurement Output  voltage  measurement Resistive  divider 
  Output  current  measurement Rogowski  coil 
 
  Waveform  record oscillograph    TDS2012C
PC  part PC Laptop  or  Table  type  IPC
  Communication Fiber  isolation
  Measurement  and  control  software Set  charge  voltage,   discharge  times,   time  interval,   auto-setting  oscillograph,   auto-achieving  oscillograph  trace,   calculating  current  and  residual  voltage  peak  value,   calculating  current  wavefront  time, half  peak  time,   negative  form  vibrate,   data  and  waveform  auto-saving 
     
Control  part
Program  control  PLC
  Preset  discharge  voltage 0.5kV~28.0kV 
Digital  voltmeter, potentiometer, comparator
  Charging  voltage  display DC  voltage  divider, digital  voltmeter
  Operation  button Charging, HV  on, HV  off
  Indicator  light HV  on

HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)
HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)
HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)

HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)
HVHIPOT Impulse Current Test System For Surge Arrester (GDCL-20kA)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier