SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine

  • Audited Supplier
  • 16 yrs

Contact Supplier

Product Highlights

  • High Efficiency Recovery: Vacuum pumping rate of 16m3/h and recycle rate of 5.8m3/h for fast gas processing.
  • Ultra-Low Leakage: Device yearly leakage rate is strictly controlled at less than 1%.
  • High Vacuum Performance: Achieves an ultimate vacuum of less than 10Pa for thorough purification.
  • Portable Design: Movable structure with compact dimensions (900x850x1650mm) and 185kg weight.
  • Multi-Function Integration: Combines compression, vacuuming, liquefaction, and purification in one unit.
  • Low Noise Operation: Noise level is kept at or below 75 dB for safer working environments.
  • Flexible Power Supply: Standard AC 220V with optional 380V power supply for diverse sites.

Product Images of SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine

SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine pictures & photos
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine pictures & photos
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine pictures & photos
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine pictures & photos
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
  • SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
  • SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
    SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
  • SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
    SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
  • SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
    SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
  • SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
    SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine

Find Similar Products

Product Description

SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine GDQH-601-15


I. General information

The Test set includes SF6 compressor, vacuum pump, condensation system, liquid storage tank, purification system built-in renewable dry filter, dust filter, ball valve, vacuum gauge, electric system, pressure detection, thermometer, alarm control and instrument panel.

It is suitable for SF6 electrical equipment, GIS manufacturer and institute.

 

II. Features

  • For local device, SF6 switch, GIS gas vacuuming and measurement.
  • For Liquefaction tank vacuumizing and measurement.
  • Vacuumizing for device itself and measurement.
  • Gas Refilled for SF6 switch.
  • Recycling SF6 gas of electric equipment including water treatment and oil treatment.
  • Dry SF6 gas of recycling or refilling and purification treatment.
  • Recycle SF6 gas of SF6 equipment and liquid storage, residual voltage measurement.
  • Compressing liquid to storage for SF6 gas.
  • Easy to move.

 
 

III. Specificaions

Mode

Frozen liquefaction, air cooling, movable

Working environment temperature

-25ºC--- +50ºC

ultimate vacuum 

<10Pa

Vacuum pumping rate

16m3/h

Recycle

Initial pressure

≤1M Pa

Terminal pressure

<0.05MPa

Rate

5.8m3/h

Air inflation

Initial pressure

<133Pa customized

Terminal pressure

≤0.7MPa 

Rate

>4m3/h

Device yearly leakage rate

<1%

Max. design pressure

4MPa

Storage tank

15L

Storage method

Gas, Liquid

Noise 

≤75 dB

Dry filter regeneration method

vacuum regeneration heating activation treatment

Power supply

AC 220V/±10%,50HZ (380V optional)

 Device total power consuption

<4KW

Dimension (mm)

900mm*850mm*1650mm

Weight (kg)

185K

SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
 
SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine

SF6 Insulation Equipment Gas Recycling Device SF6 Gas Recovery Machine
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249016". Items marked "verified" are certified.

Watch Video
Watch Video
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.
HV Hipot Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Building A1-3, Kechuang Center, Chuanggu Road, Dongxihu District, Wuhan, Hubei, China
verified Plant Area
2712 square meters
verified Number of Employees
68
verified Registered Capital
31,130,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Wuhan Port

Our Production Capability & Technical Expertise

verified Main Products
Transformer Testers, Partial Discharge Test System, Insulation Tester, High Voltage Test Set, Switchgears Test Set
verified ODM Service Available
Yes
verified R&D Engineers
8 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-11-08
Export Year
2011-07-01
verified Main Markets
North America, South America, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Annual Export Revenue
6,000,000 RMB
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What is the maximum design pressure of the device?
The maximum design pressure is 4MPa.
What is the storage capacity of the tank?
The storage tank has a capacity of 15L and supports both gas and liquid storage methods.
What is the annual leakage rate of the SF6 gas?
The device yearly leakage rate is less than 1%.
Does the manufacturer offer ODM services?
Yes, ODM service is available for this product.
What is the typical lead time for production?
The average lead time is one month, regardless of peak or off-peak seasons.
What is the total power consumption of the device?
The device total power consumption is less than 4KW.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now