Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GDPD-306M is widely used in the partial discharge detection of power systems. Including high voltage switchgear, ring mains, voltage/current transformer, transformer (include dry type transformer), GIS, overhead lines, cables, and other equipment insulation state detection.
The following indicators are used to measure the degree of discharge of electrical equipment:
Partial discharge intensity detection: By measuring the discharge signal in a power frequency cycle, the intensity of the partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence.
Partial discharge frequency detection: The device measures the discharge signal within a power frequency cycle, extracts the discharge pulses and characterizes the frequency of partial discharges according to the number of discharge pulses.
Specifications
TEV Measurement | UHF Measurement | ||
Measurement range | 0-60dBmV | Detection frequency band | 300~1500MHz |
Resolution | 1dB | Measurement range | -75-0dBmV |
Accuracy | ±1dB | Accuracy | <1dBmV |
Max. pulse per cycle | 1400 | Sensor frequency band | 300-2000MHz |
Measurement frequency band | 1~100MHz | ||
AA measurement | AE measurement | ||
Measurement range | -6dBμV~68dBμV | Measurement range | -6dBμV~68dBμV |
Resolution | 1dB | Resolution | 1dB |
Accuracy | ±1dB | Accuracy | ±1dB |
Sensor center frequency | 40kHz | Frequency range | 40-200kHz |
HFCT measurement | |||
Sensor transmission impedance | 5mV/mA | ||
Detection frequency | 1~30MHz | ||
Sensitivity | ≤50pC | ||
Hardware | |||
Shell | ABS | ||
Display | 4.0inch RGB LCD screen | ||
Controller | ARM | ||
Connector | USB interface (charger port), Wireless WIFI 3.5mm stereo headphone jack, Wireless synchronization benchmark External ultrasonic sensor input |
||
Headphone | 8ohm minimum | ||
SD card | Standard 16G | ||
Built-in battery | 3.7V/1Ah lithium battery | ||
Working time | About 8 hours | ||
Charger | AC 90-264V or DC 5V | ||
Working temperatures | -20~+50ºC | ||
Humidity | 20~85% relative humidity | ||
Dimension, weight | 210*100*35(mm), 0.4kg (main unit) |
Main unit |
1 |
Standard |
External Contact ultrasonic sensor |
1 |
For option, used for transformers, GIS, motors |
UHF sensor |
1 |
For option, used for GIS |
HFCT |
1 |
For option, used for power cable |
Test cable |
1 |
Standard |
Charger |
1 |
Standard |
USB cable |
1 |
For charging and PC communication |
User's guide |
1 |
|
Factory test report |
1 |