GDYM-3F HV HIPOT Comprehensive Electric Energy Meter Calibrator

Product Details
Customization: Available
After-sales Service: yes
Warranty: 1 year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • GDYM-3F HV HIPOT Comprehensive Electric Energy Meter Calibrator
  • GDYM-3F HV HIPOT Comprehensive Electric Energy Meter Calibrator
  • GDYM-3F HV HIPOT Comprehensive Electric Energy Meter Calibrator
  • GDYM-3F HV HIPOT Comprehensive Electric Energy Meter Calibrator
  • GDYM-3F HV HIPOT Comprehensive Electric Energy Meter Calibrator
  • GDYM-3F HV HIPOT Comprehensive Electric Energy Meter Calibrator
Find Similar Products

Basic Info.

Model NO.
GDYM-3F
Power supply
AC 55V - 600V
Power consumption
< 9W
Voltage range
25-600V
Voltage error
±0.05%
5A terminal accuracy
±0.05%
5A clamp accuracy
±0.5% H (H=1+0.01K K=2-51)
Big clamp accuracy
±0.5%
Ratio measurement
±0.5%
Voltage influence
< ±0.01%
Rechargeable battery
11.1V 3000mAh
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan China
Production Capacity
5000 Sets/Year

Product Description

Features
  • Simultaneously calculating all parameters of full-wave, fundamental and harmonic wave. In the calibration interface, real-time display of U, I, P, Q, VA, phase angle of full wave fundamental waves, synthesis U, I, P, Q, VA and percentages of harmonics, positive, negative and zero sequence content of U and I, PH+, PH-, PH+/P base%, PH-/ P base% of harmonic, PF of full wave, fundamental wave and harmonic wave.
  • 7 kinds of calibration mode, including full wave active power, full wave reactive power, fundamental wave active power, fundamental wave reactive power, fundamental wave apparent power, full wave apparent power, harmonic active power. Not only can verify the accuracy of the active energy of the full wave meter, the fundamental wave meter and the harmonic meter as well as the accuracy of the reactive energy of the full wave meter,and the fundamental wave meter. But also can verify the accuracy of the apparent electric energy meter.
  • Choose any harmonic or multiple harmonics to calculate the combined U, I, P, Q, VA, and percentages, as well as harmonic active energy.
  • The contents and measured values of U, I, P, Q and VA of the three-phase harmonics can be separately and simultaneously analyzed to display the 51st harmonic PH+, the harmonic PH- and the percentage of the fundamental wave, to determine the impact of the positive and reverse harmonic active power on the measurement.
  • Full-wave reactive power is the algebraic sum of fundamental and harmonics reactive power. Avoid the past 90 degree phase shift method, under the harmonic reactive power measurement error situation. The frequency of the harmonic can be selected according to the measurement bandwidth of tested energy meter.
  • Two-way detection pulse can be detected at the same time, the constant, working mode and pulse numbers of the detected pulse can be completely different.
  • 2.4 times overload, all measurement points to ensure the accuracy of 0.05%, to ensure the measurement index when CT secondary rated current is 1A .
  • 500 times current range to ensure measuring index, 10000 times current display range. Minimum 1mA start current. Under Massive Quantity Power Supply and Measurement , no load can also identify the wiring.
  • Electric energy accumulation function can check the electric energy meter without electric energy pulse output.
  • Display vector diagram, identify three wire of 48 kinds, four wire of 96 kinds of wrong wiring and CT second cross wiring.
  • 7-inch 16: 9 industrial TFT wide color touch screen. Each function of the instrument is one screen display, the user can see all the parameters of each function on one screen.
  • In the case of no voltage and current signal, the instrument can simulate all kinds of wiring in the office, and get the corresponding wiring result and correction coefficient. This function can be used as a training tool for line lookup, and improve the line checking skills of the staff.
  • The instrument can produce 0.05A-5A of the actual current signal applied to the 5A clamp to measure the error of the clamp. The problem of 5A clamp error changes after the longer use time has been solved. It is possible to know the closure of the clamp at any time and remind the staff to clean the jaws. When the 5A clamp is replaced, the error can be corrected to the 0.2 level.
  • Automatic entry power meter number (Optional function)
    The bar code scanning gun is supported, and the number of electric energy meter is automatically encoded.
  • Uses 485 or infrared photoelectric head, read multi-function power meter tip, peak, flat, valley, the total active and reactive power base, read the constant and the time-correct. Support GB DL645 Statute DL645-1997 and DL645-2007. (Optional function)
  • Built-in 2G electronic disk.
  • With a 3 inch spot printer, battery powered, directly convert color screen images to black and white and then print.
  • With 5A, 100A, 500A, 1000A clamp, direct measurement of low-voltage current transformer ratio and ratio error.
  • Display the voltage and current waveforms of A, B, C three-phase.
  • Operating power input range 55V-600V. The rated voltage of the three phase voltage input industrial socket is 600V.
  • All the parameters that need to be entered on the scene and the download data can be defined by the user freely. Can download 5000 user data.
  • The current screen can be stored to U-disk.
  • With the function of measuring temperature and humidity.
  • With USB interface, connect the USB to form a super large space, convenient for data copy.
  • Touch screen plus key operation, input keyboard adopts computer keyboard arrangement. The user can also use the PC computer keyboard of the USB interface.
  • Carry on right time with PC through the instrument USB interface.
  • The tablet computer can control the instrument directly, and the operating interface is the same as the instrument.
  • Voltage measurement sockets and power switching switches are industrial level and can be used under 600V. (ordinary city power switch is 250V, 380V is used in super range, there is a hidden danger)
  • High safety design. The city electric socket, voltage measurement socket, current input and current clamp input are separately isolated, and the withstand voltage is 4kV.
  • Electric energy pulse input protection. It can protect automatically when input high voltage and display prompt information on the instrument. After correcting the error, the click interface can reset the protection.

Specifications
 

Voltage
Guarantee error range 25-600V
Starting measuring value 0.5V
Rated value 440V
Error accuracy ±0.05%


Current
Terminal Rated Ie 5A
Range 0.025A-12A
Clamp Rated Ie 5A, 100A, 500A, 1000A
Range 0.5%le-2.4le
Starting current 0.02%le
Input frequency range 45-65Hz
Frequency measuring error ±0.01Hz
Phase angle measuring range -180°-180°
Max. Phase angle error ±0.1°
Harmonic percentage, harmonic electrical parameters, and harmonic electric energy measurement times 2-51 times
Pulse constant
(Note: Ie is rated current)
Low frequency output (3 gears) 5A 3600P, 36000P, 360000P/kWh(kvarh, kVAh)

others
3600P, 36000P, 360000P *(5/Ie)P/kWh
(kvarh, kVAh)
Internal high frequency 5A 1.8x109P/kWh

Other current gears

1.8x109*(5/Ie)P/kWh
Maximum pulse input frequency 50kHz


5A terminal
Full-wave fundamental wave
kWh, P, U, I
±0.05%
Full-wave fundamental wave
Kvarh, Q, VA, VAh
±0.2%
Harmonic wave U, I, P, Q, S ±0.2%H (H=1+0.01k  K=2-51)




5A Clamp
Full-wave fundamental wave
kWh,P,U,I
±0.2%
Full-wave fundamental wave
Kvarh,Q,VA,VAh
±0.2%
Harmonic wave      U,I,P,Q,S ±0.5% H (H=1+0.01k  K=2-51)
Self checking current cyclic output current 0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A
Self checking error (linear and angular difference) ±0.1%


Big current clamp
 
Full-wave fundamental wave kWh,P,U,I ±0.5%
Full-wave fundamental wave
 Kvarh,Q,VA,VAh
±0.5%
Harmonic wave      U,I,P,Q,S ±1.0% H (H=1+0.01k  K=2-51)
Others Ratio measurement ±0.5%
Voltage influence < ±0.01%
Frequency influence < ±0.01%
Temperature influence < ±0.005%/ºC
24 hours change error < ±0.01%
Harmonic influence < ±0.01%
Rechargeable battery 11.1V 3000mAh
Withstand voltage (Voltage current measurement and power supply and low-voltage terminals) 4.0 kV
Electrical Fast Transient Burst 4.0 kV
Surge 4.0kV (Common mode),
2.0kV (Differential mode)
GDYM-3F HV HIPOT Comprehensive Electric Energy Meter Calibrator
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now