| Rated voltage | ±300kV |
| Rated energy | 30kJ |
| Total stage | 3, stage energy 10kJ |
| Charging voltage of each stage | ±100kV |
| Capacitance of each stage | 20μF, 100kV dry type full insulation sealing |
| Output waveform | 1.2±30%/50±20%μs standard lightning full wave, efficiency>90%, 2-6μs standard lightning chop wave |
| Synchronizing range | ≥20%, when stage voltage is whthin 15%-100% rated voltage |
| Duty cycle | Continuous working when the voltage is <80% rated Discontinuous working when the voltage is >80% rated |
| Synchronizing discharge maloperation | <1% |
| Min. Output voltage | ≤10% of nominal voltage |
| Base | 2M*1.5M (movable wheel), Height: about 2M. Weight: about 560kg |