Auto CT PT Calibrator with Accuracy Class 0.01 to 10

Product Details
Customization: Available
Usage: test CT/PT
Power: Electricity
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO 45001:2018
Export Year
2011-07-01
  • Auto CT PT Calibrator with Accuracy Class 0.01 to 10
  • Auto CT PT Calibrator with Accuracy Class 0.01 to 10
  • Auto CT PT Calibrator with Accuracy Class 0.01 to 10
Find Similar Products

Basic Info.

Model NO.
GDHG-103
Certification
CE
Calibrate CT/PT Accuracy
Class 0.01 to class 10
CT Secondary Rated Current
5A, 1A
PT Secondary Rated Voltage
100V, 100/3V, 150V(100/3V, 220V)
Delivery Time
30 days
Transport Package
Export Package
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
HS Code
9030841000
Production Capacity
5000 Sets/Year

Product Description

General introduction

GDHG-103 CT/PT Calibrator is mainly used to calibrate CT/PT with accuracy class 0.01 to class 10, CT secondary rated current is 5A, 1A and PT secondary rated voltage is 100V, 100/√3V, 150V(100/√3V,220V). The test result is shown directly by figure.


Auto CT PT Calibrator with Accuracy Class 0.01 to 10

Features

  • Display, save and print data.
  • Automatic measurement, using difference value measurement method and direct measurement error.
  • Automatic polarity judgment, automatically determine the polarity within 2%-20%
  • Automatically switch range according to measurement data.
  • Strong adaptability for power supply.
  • 320*240 LCD screen with back light.
  • AC sampling and full data processing.
  • With data management function. It can be connected with PC.
  • Save and check measurement result. Data will not lose after power off .


Optional components

  • Standard PT
  • Standard CT
  • Self-boosting standard transformer
  • Standard CT with current injector
  • Control unit with double voltage regulator
  • Inductive divider
  • PT load case
  • CT load case


Specifications

Measurement Range In-phase component(%): 0.0001-200, resolution 0.0001
Quadrature component(min): 0.001-700.0, resolution 0.001
Impedance(Ω): 0.001-20.0, resolution 0.0001
Admittance(ms): 0.0001-20.0, resolution 0.0001
Accuracy Basic error
In-phase component: ΔX=±(X×2%+Y×2%)±Dx
Quadrature component: ΔY=±(X×2%+Y×2%×34.48)±Dy
X,Y-- Display value of instrument
Dx, Dy-- Quantization error
lError of Percent table: 1.5% (1.0% for option)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier